Technical Data
Base unit
Model: WT2079
Power consumption: 5.0V
150 mA
Power supply: 3 x LR03 (AAA) / 1.5 V
Temperature measuring range: 14.2°F ~ 122°F
Resolution: 0.2°F
Humidity measuring range: 1 % to 99 % relative humidity
Humidity measuring accuracy: +/-1 %
Resolution: 1 %
Wireless sensor
Model: WT2022B
Batteries: 2 x LR6 type (AA) 1.5 V
Temperature measuring range: - 40°
F to 158°
F
Protection type: IPX4: Protection against splash water from all directions
Humidity measuring accuracy: +/- 1%
Transmission frequency: 43
3
.92
MHz
Range: max. 328 ft (100 meters) (in open area)
Power adapter
Input: 120VAC 60Hz 50mA 7W
Output: 5.0VDC 150mA
As our products are constantly evolving and improving, changes in the design and