SP
+
ATEX MF
Appendix
Revision: 07
2022-D014984
en-43
10.6.4 Technical data for SP
+
140 for use in potentially explosive atmospheres
Operating noise L
PA
[dB(A)]
(For n
1
= 3000 min
-1
w/o load)
–
≤ 60
Max. permissible housing temperature
[°C]
–
+80
Ambient temperature [°C]
–
see chapter 10.4 "Specifications for
Lubrication
–
synthetic gear oil (see also Chapter 7.1
Direction of rotation
–
In- and output same direction
Mass moment of inertia J
1
[kgcm
2
]
Refers to the drive
14
0.38
0.38
0.54
0.37
0.37
19
0.55
0.54
0.38
0.54
0.54
28
1.8
1.8
1.91
1.8
1.8
a
In the case of mounting position V1, reduce the average drive speed n
1N
by 20%.
b
No-load running torques diminish during operation
c
Refers to the center of the output shaft or flange
Tbl-29: SP
+
100, 2-stage, i = 40 – 100: Technical data for use in potentially explosive atmospheres
Technical data for SP
+
140, 1-stage
Clam-
ping
hub Ø
[mm]
Ratio i
3
4
5
7
8
10
Max. acceleration torque T
2B
[Nm]
(max. 1000 cycles per hour)
24
273
528
528
528
371
371
32 / 38 /
48
273
528
528
528
371
371
Nominal output torque T
2N
[Nm]
(At n
1N
)
–
202
335
333
319
215
215
Emergency stop torque T
2Not
[Nm]
(1000 times possible during the
service life of the gearbox)
24
454
605
710
710
560
710
32 / 38 /
48
710
710
710
710
560
710
Permissible average input
speed n
1N
[min
-1
]
(At T
2N
)
a
–
1150
1200
1200
1600
1700
1700
Max. input speed n
1Max
[min
-1
]
–
2500
2500
2500
2500
2500
2500
Technical data for SP
+
100, 2-stage, i = 40 – 100
Clam-
ping
hub Ø
[mm]
Ratio i
40
50
64
70
100