SP
+
ATEX MF
Appendix
Revision: 07
2022-D014984
en-45
Technical data for SP
+
140, 2-stage, i = 16 – 35
Clam-
ping
hub Ø
[mm]
Ratio i
16
20
25
28
32
35
Max. acceleration torque T
2B
[Nm]
(max. 1000 cycles per hour)
–
528
528
528
528
528
528
Nominal output torque T
2N
[Nm]
(At n
1N
)
–
360
360
360
360
360
360
Emergency stop torque T
2Not
[Nm]
(1000 times possible during the
service life of the gearbox)
–
710
710
710
710
710
710
Permissible average input
speed n
1N
[min
-1
]
(At T
2N
)
a
–
1900
1900
1900
1900
1900
1900
Max. input speed n
1Max
[min
-1
]
–
2500
2500
2500
2500
2500
2500
Average no-load running
torque T
012
[Nm]
(For n
1
=3000 min
-1
and gearbox
temperature 20 °C)
b
–
2.4
2.1
2.0
1.8
1.6
1.2
Max. backlash j
t
[arcmin]
–
Standard ≤ 5 / Reduced ≤ 3
Torsional rigidity C
t21
[Nm/arcmin]
–
53
Max. axial force F
2AMax
[N]
c
–
6900
Max. lateral force F
2QMax
[N]
c
–
6600
Max. tilting moment M
2KMax
[Nm]
–
660
Service life L
h
[h]
–
see chapter 7.2.4 "Replacing the gearbox"
Weight incl. standard adapter
plate m [kg]
–
17
Operating noise L
PA
[dB(A)]
(For n
1
= 3000 min
-1
w/o load)
–
≤ 63
Max. permissible housing
temperature [°C]
–
+80
Ambient temperature [°C]
–
see chapter 10.4 "Specifications for startup and
Lubrication
–
synthetic gear oil (see also Chapter 7.1
Direction of rotation
–
In- and output same direction