S

AFETY INSTRUCTION

 

 

Read this safety instruction and the manual first 

 

Follow all instructions and information. 

 

Do not lose this manual. 

 

Do not use this apparatus under the rain or near the water. 

 

Do not install the apparatus near heaters or in hot environments, do not use outside the 
operating temperature range. 

 

Do not open the apparatus, only qualified service technician are enabled to operate on it. 
The apparatus needs servicing when it is not properly working or is damaged by liquids, 
moisture or other objects are fallen in the apparatus. 

 

Use only accessories or replacement parts authorized or specified by the manufacturer. 

 

Clean the apparatus only with dry cloths, do not use liquids. 

 

Report the serial number and the purchasing date in front of the manual. It is needed to 
have proper replacement parts or accessories from the manufacturer. 

 

When replacement parts are needed, use only replacement parts authorized from the 
manufacturer. Substitution with not authorized parts could result in electric shock, 
hazards or fire. 

 

Keep attention on all the labels with warnings or hazards on the apparatus. 

L

ED INDICATIONS

 

Led indication with bi-colour led (red & green) on wireless power switch (1) and in front led (2): 

Wireless transmission status: green when RF transmission power is on. 

Battery status: green steady, slowly blinking (< 25%), quickly blinking (<12%). 

Modulation peek (if activated): red.  

Ptt status: red if active (push to talk “pushed”). 

B

ATTERIES

 

MTP40 

Lite

 is working with 2 AA alkaline or NiMH batteries (select correct type on setup 

controls). Battery status can be checked on internal OLED display or looking to LED status on 
power switch (see 1.1).  

BATTERY SUBSTITUTION  

 

Open transmitter cover and insert batteries following polarity indicated.  

Attention: always replace both the batteries 

Summary of Contents for MTP40

Page 1: ...MTP40 Lite User Manual Wideband Wireless Professional Pocket Transmitter SN ________________ Rev 02 rif FW 1 10 0L Author Support Date 22 October 2014...

Page 2: ...Fig 1 Switch to enable wireless transmission it also indicates the battery status and peak mute operation with PTT In order to allow front visibility same colour information on 1 is replicated with t...

Page 3: ...ded to have proper replacement parts or accessories from the manufacturer When replacement parts are needed use only replacement parts authorized from the manufacturer Substitution with not authorized...

Page 4: ...ons gain D 3 position selector up down click Fig 3 OLED POWER UP OLED IS IN OFF CONDITION Pushing down selector click oled turns on A first menu with serial NO and brand logo is displayed then status...

Page 5: ...0 H 542 000 640 000 I 566 000 686 000 L 678 000 798 000 K 520 000 640 000 Name AUDIO AF In Gain 20 40 dB 1dB step HPass Filter flat 60 80 120 170 250 400Hz MIC Mode 2 wires 2wires bias 3 wires 2wires...

Page 6: ...enu displayed after power up Major info are displayed Current channel group i e CH 00 GR 08 Current frequency i e 566 075 MHz Mic gain i e AF 04 dB and high pass filter i e HP 60 Hz RF H or RF L on to...

Page 7: ...se the selector to change values and click to confirm MIC menu This menu can be entered by scrolling selector Following Mic mode can be setup for LEMO option 2 wires PTT is possible for external audio...

Page 8: ...lose to saturation can be enabled disabled Battery type can be setup in Alkaline or NiMH IRDA menu This menu can be entered by scrolling selector While is this menu MIC can be connected to IRDA for se...

Page 9: ...nd Disable when the PTT button is pushed nothing happen the transmitter sends AF Tone squelch Normal when the PTT button is pushed the transmitter send a different RF signal According to the receiver...

Page 10: ...ata None Mod Peak PTT 2 wires bias 1 GND 3 AF 5 5V 20 40 dB Disable Normal Muting No data None Mod peak PTT 3 wires 1 GND 2 5 5V 3 AF 40 40 dB Disable No data None Mod peak 2 wires phantom 1 GND 2 3 1...

Page 11: ...to a PHA48 to use microphone with XL3 48V connection CAL120 AF cable 120cm LEMO 3pole XLR 3F connectors PHA48 Plug on for XLR3 Mic with 48V Phantom power To be used with CAL48 connected to an MTP30 40...

Page 12: ...ceiver MRK950 MRK960 to the PC thru USB connection run the program enable the IRDA communication on the transmitter see IRDA menu NOTE Wisycom IR Programmer doesn t work whit MRK950 MRK960 if it is co...

Page 13: ...sful connection is signaled with the interface connection green led while a failed connection is signaled with the communication error led Once a supported device is found the software automatically r...

Page 14: ...nnel double click on the grid frequency panel row channel s number insert the new frequency value and press OK button To lock hide a specific channel double click on the grid frequency panel NOTE keep...

Page 15: ...on at the bottom of the panel it is possible to load save the frequencies for the selected group from to a wdf file To save the frequencies of all the groups click to the related button above The lega...

Page 16: ...save action NOTE a trick In case of the user have a locked parameter and he is in great need for modify it he can save the configuration to USER configuration by OLED see PRESET menu and then load th...

Page 17: ...6 dBu peak gain selectable 40 40 54 dBu 26 dBu peak gain selectable 20 40 54 dBu 6 dBu peak 5 5 V on 4k7 bias supply AF input level 80 dB adjustable range from 60 dBu 775 uV to 26 dBu 15 5 V at peak d...

Page 18: ...batt Note MTP40 Lite transmitter complies with ETS 300 422 GND 5 5V 3 wires AF AF 5 5V 2 wires Option L Lemo Conn OPTION CODE MTP40 X YZ AUDIO CONNECTOR X L 3 PIN LEMO CONNECTOR use FVB 00 303 NLAE24...

Page 19: ...MTP40 Lite User Manual Rev 02 19 DECLARATION OF CONFORMITY...

Page 20: ...Wireless System Communications Via Spin 156 I 36060 Romano d Ezzelino Italy Tel 39 0424 382605 Fax 39 0424 382733 www wisycom com e mail sales wisycom com...

Reviews: