After few seconds, scan results are displayed on a histogram.
Each column of the histogram is divided into two parts by a
black line. The lower part indicates the number of
free
channels (RF level
<
Squelch level - 6dBµV) in the group, while
the upper one the number of channels
almost free
(Squelch level
<
RF level
<
Squelch level - 6dBµV).
We recommend to choose the group with the highest number
of free channels.
Press SEL to select the desiderate group and choose the
channel as in “
After the selection of the desired channel, a screen appears
with the selected frequency, channel and group and it is
possible to Set or Synchronize the receiver with the
transmitter. We recommend setting the frequency and then
synchronize it with the transmitter.
Freq
The Frequency scan allows to select a range of frequency to
scan, between a maximum and a minimum value and the step
with which to perform the scans. Press and hold the SEL
button to select the group to scan.
Then it prompts to turn off all transmitters.
So press SEL to start the scan!
After few seconds, scan results are displayed on a chart in
ascending order according to the frequency (step 1MHz). The
dotted line in the graph indicate the squelch threshold.
Pushing simultaneously UP and DOWN button it’s possible to
zoom the graph to show all the steps of scan
After the selection of the desired frequency, a screen appears
with the selected frequency and the RF level and it is possible
to Set or Synchronize the receiver with the transmitter. We
recommend setting the frequency and then synchronize it
with the transmitter.