7. Name Plate

Summary of Contents for PT863

Page 1: ...Ultra High Purity Pressure Transmitter Manual PT863 Standard Type English ...

Page 2: ...perating Temperature Tamb 20 80 C Excessive temperature could cause the malfuction of the transmitter and measuring error If explosive gas is present use correspoing enviromental entity approved products and do not disassemble or assemble the transmitter in such area Before disconnecting the transmitter user must make sure that the valve is closed so the measuring fluid would not leak The leakage ...

Page 3: ...e and Size Each Part Name and Working Principle Ground Connection Name Plate Diagram and Wiring Transfer Storage and Cautions for Opening the Package Connection Area Maintenance and Operating Cautions Safety Measures Limited Warranty and Limitation of Liability 04 04 04 05 07 07 08 09 10 10 11 11 11 Contents English ...

Page 4: ...1 Year Slim Design Accrracy within 0 25 4 20 mA Output Current 2 Characteristics 1 2 3 4 5 6 7 8 9 10 11 Power Working Temperature Temp Compensation Allowed Humidity Allowed Altitude Power Consumption Process Material Measuring Range Accuracy Material Method to attach Label 12 24 V DC 20 80 C PT863 20 60 C Below 85 Below 1000 m 4 20 mA Fluid Gas 15 30 psi Min 15 3000 psi Max Span 0 25 Process mdei...

Page 5: ...05 English 4 Process Connection Type and Size 1 1 PT861 PT862 PT863 ...

Page 6: ...06 English 1 2 PT861 PT862 PT863 ...

Page 7: ...hould be connected to rebar floor or Bus Bar Ground Point should be considered with a local Industrial regulation and Electric standards 6 Ground Connection 1 Each Part Name 2 Working Principle Pressure applied to the pressure input section and the pressure value will convert into an electronical singal Measured pressure will be transferred after converting into 4 20 mA electrical current If requi...

Page 8: ...08 English 7 Name Plate ...

Page 9: ...09 English 1 Diagram 2 Wiring 8 Diagram and Wiring Transmitter Power Supply Indicator PLC or Data Gathering System RED BLACK 1 4 2 3 RED Standard CABLE BLACK FG WHITE 1 4 2 3 BROWN M12 CABLE BLUE ...

Page 10: ...eanroom 9 Transfer Storage and Cautions for Opening the Package 1 2 3 4 5 6 7 For safe use avoid humid vibration and corrosive gas in the installation area Avoid area where it can excess the temperature listed on the manual For choosing installation site Please consider the possibility of Lightning and steam damage Avoid a direct sunlight In case of installing on the pipe use a proper spanner Do n...

Page 11: ...ransmitter for the examination If Transmitter is worn out it is exposed to any other harsh environment then the measuring error could be found it is recommended to replace the Transmitter Consult licensed Technician for repair to avoid fire electric shock or injury 11 Maintenance and Operating Cautions 1 2 3 4 5 6 7 This product should not be treated as unclassfied industrial waste To prevent the ...

Page 12: ......