![Wireless Devices POCSAG Y1707RS Operation Manual Download Page 6](http://html.mh-extra.com/html/wireless-devices/pocsag-y1707rs/pocsag-y1707rs_operation-manual_988493006.webp)
6
Y1707RS/TTL [Version 1.3]
<<Remote Controller’s Application Sections >>
A. How to issue the command to your paging remote controller
Please access a paging call attempt with the following messages.
PPPP A C C RRRRR
Preventing the incorrect key inputs [PPPP + ACC + RRRRR = 12 Digits
(must)
].
PPPP
= Password (0001~9999)
A
= Output Port Number.
A=1 = Relay #1.
A=2 = Relay #2.
A=0 = Relay #1 + Relay #2.
CC
= Output Status (
Remark: H=Relay Active, L=Off, T=Times, Z=Endless)
00 = Always L
01 = Always H
12 = H2S/1T
13 = H1S/L1S/3T
14 = H2S/L2S/4T
15 = H10S/L10S/Z
16 = H20S/L20S/Z
17 = H1S/ L1S/Z
18 = H0.5S/L0.5S/Z
19 = H6S/L1S/Z
21 = H0.25S/L10S/H0.5S/L10S/H1S/L10S/H2S/L10S/H.Z
22 = H0.5S/1T
23 = H3S/1T.
24 = H20S/1T.
25 = H3S/L3S/10T.
26 = H2S/L2S/20T.
27 = H1S/L1S/30T.
28 = H0.5S/L0.5H/30T.
29 = H30S/1T.
31 = H0.5sec/1T
32 = H1sec/1T
33 = H3sec/1T
34 = H5sec/1T
35 = H8sec/1T
36 = H10sec/1T