C. How to programming the Y1707RS/TTL 

1).Connect the DC plug and RS-232 plug into Y1707 (or Y1707 Programmer) 
2).Connected the RS-232 cable from Y1707 to P/C or N/B 
3).Install programming CD software into your P/C or N/B 
4) Click [Pager Module programming Kit-y1707V1] to run the Y1707 data 
programming process. 

 

 

Programming Manual of Y1707 

 

1. Frequency

:

 

This set-up is used for the reference information only: It does not affect any 
Technical features contained in the Y1707 unit. 

2. 

Y1707 Address (Cap Code) Set-Up

:

   

There are total 6 addresses in this unit with each address range from

:

 

z

 Addr 

1

:

 set from 0000008 to 2097151. And it must key in 0 digit if disable.

 

z

 Addr 

2

:

 set from 0000008 to 2097151. And it must key in 0 digit if disable. 

z

 Addr 

3

:

 set from 0000008 to 2097151. And it must key in 0 digit if disable. 

z

 Addr 

4

:

 set from 0000008 to 2097151. And it must key in 0 digit if disable. 

z

 Addr 

5

set from 0000008 to 2097151. And it must key in 0 digit if disable. 

Summary of Contents for POCSAG Y1707RS

Page 1: ...1 POCSAG Wireless Data Receiver Model No Y1707RS TTL Operation Manual Wireless Devices Inc Taiwan ...

Page 2: ...s well as a RS 232 serial port output Application Data Receiver Remote Controller Car Burglar Alarm Telemetry Data Monitor Advertisement Panel Taxicab Call message LED Display Panel Any remote application Main Function 138MHz 174MHz 430MHz 470MHz 929MHz 933MHz POCSAG Baud 512bps 1200bps 2400bps Built in RS 232 Driver Built in 6 Ports On Off Output to Driver Relays Data output TTL or RS 232 Output ...

Page 3: ...MHz by crystals Oscillator No tune bandwidth 10Mhz VHF 20MHz UHF Frequency stability 2 5ppm standard Channel spacing 12 5kHz or 25kHz Demodulation FSK NRZ POCSAG format 512 1200 or 2400 Bps Selectivity 55dB Inter modulation rejection 60dB PLL step size 12 5K 25K Sensitivity 106db M 512bps 105db M 1200bps 103db M 2400bps User Interfaces Serial RS 232 2400 Bps Parallel 8 discrete outputs TTL levels ...

Page 4: ...r TXD TTL RXD TTL ON OFF PULSE Outpou Port 1 6 Receiver Data output to P C DB9 pin 2 Data input from P C to P C DB9 pin 3 TTL Data Output Option TTl Data Input Option 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Red Power Green On Air Phone Jack RS 232 DC Jack J1 J3 LED RY1 RELAY DPDT RY6 RELAY DPDT 12 Any DC 12 V Relays System ground to P C DB9 pin 5 Remoto Controller Application Section Data Applicati...

Page 5: ...J2 2 O 2 for Port 2 output to drive to relays J2 3 O 3 for Port 3 output to drive to relays J2 4 O 4 for Port 4 output to drive to relays J2 5 O 5 for Port 5 output to drive to relays J2 6 O 6 for Port 6 output to drive to relays J2 7 8 16 for DC power Input DC 6 13 V J2 9 10 System ground for power V J2 11 Ground for RS 232 Connect with Computer Pin 5 of RS 232 DB9 J2 12 TXD for data output Conne...

Page 6: ...99 A Output Port Number A 1 Relay 1 A 2 Relay 2 A 0 Relay 1 Relay 2 CC Output Status Remark H Relay Active L Off T Times Z Endless 00 Always L 01 Always H 12 H2S 1T 13 H1S L1S 3T 14 H2S L2S 4T 15 H10S L10S Z 16 H20S L20S Z 17 H1S L1S Z 18 H0 5S L0 5S Z 19 H6S L1S Z 21 H0 25S L10S H0 5S L10S H1S L10S H2S L10S H Z 22 H0 5S 1T 23 H3S 1T 24 H20S 1T 25 H3S L3S 10T 26 H2S L2S 20T 27 H1S L1S 30T 28 H0 5S...

Page 7: ...2 H2hr 1T 53 H3hr 1T 54 H4hr 1T 55 H6hr 1T 56 H8hr 1T 57 H12hr 1T 58 H13hr 1T 59 H24hr 1T If A C C 0 0 0 All Relays Off RRRRR Customer ID These 5 digital ID are to secure the correct message commands which must only be set by via the P C programming Example for making the command Message 2222 1 01 12345 Password 2222 PPPP 1 Relay 1 A 01 ON CC 12345 customer ID RRRRR ...

Page 8: ...he messages as below PPPP NNNN PPPP PPPP Old Password 0001 9999 NNNN New Password PPPP Old Password 0001 9999 Preventing the incorrect key inputs PPPP ACC RRRRR 12 Digits must Example for changing the password 1111 2222 1111 Old Pass word 1111 PPPP New Pass Word 2222 NNNN ...

Page 9: ... 4 O 5 O 6 RXD RS232 DB9 3 TXD RS232 DB9 2 GND RS 232 DB9 5 V 6 24V V 6 24V GND Power 8 7 6 5 4 3 2 1 16 15 14 13 12 11 10 9 SIDE TOP 2 54X8X2 J2 TXD TTL for option RXD TTL for option 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Type 2 NC NC NC GND Power LOOP WITH 11 RS232 RX from PC ON Air LED Indicat NC RS232 TX to PC loop with 4 V 6 24V NC GND RS 232 GND 1 2 3 4 5 6 7 8 9 10 11 12 13 14 14 13 12 11 1...

Page 10: ... for option 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Type 6 V 6 24V GND Power O 1 O 2 O 3 O 4 O 5 O 6 RXD RS232 DB9 3 TXD RS232 DB9 2 GND RS 232 DB9 5 V 6 24V V 6 24V GND Power 8 7 6 5 4 3 2 1 16 15 14 13 12 11 10 9 SIDE TOP 2 54X8X2 J2 TXD TTL for option RXD TTL for option 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Type 7 RXD RS232 DB9 3 TXD RS232 DB9 2 GND RS 232 DB9 5 V 6 24V Power 6 5 4 3 2 1 TOP 2 ...

Page 11: ...6 Type 9 RXD RS232 DB9 3 TXD RS232 DB9 2 GND RS 232 DB9 5 V 6 24V Power 6 5 4 3 2 1 TOP 2 54 X 6 TXD TTL for option RXD TTL for option J2a 1 2 3 4 5 6 Type 10 RXD RS232 DB9 3 TXD RS232 DB9 2 GND RS 232 DB9 5 V 6 24V Power 6 5 4 3 2 1 TOP 2 54 X 6 TXD TTL for option RXD TTL for option J2a 1 2 3 4 5 6 You can select from with housing or without housing ...

Page 12: ... reference information only It does not affect any Technical features contained in the Y1707 unit 2 Y1707 Address Cap Code Set Up There are total 6 addresses in this unit with each address range from z Addr 1 set from 0000008 to 2097151 And it must key in 0 digit if disable z Addr 2 set from 0000008 to 2097151 And it must key in 0 digit if disable z Addr 3 set from 0000008 to 2097151 And it must k...

Page 13: ...eceiving messages by adding the programmed Characters at The start of the text 7 At the End of The Text This is to distinguish each receiving messages by adding the programmed Characters at the end of the text 8 Power Saving Set Up Enable stands for the power ON Off ON Off And the disable means The power output always ON Remark This feature is reserved for the PDA operation only 9 Baud Rate Set Up...

Page 14: ...rogrammed data out from Y1707 unit 18 EXIT Function To exit this programming software 19 Command Buffer Set Up For engineer use only 20 Com Port Pool The Y1707 s receiving data can be monitored in this screen And The other way to view these data is to activate the Hyper terminal screen under the MS windows operational software Wireless Devices Inc Taiwan ...

Reviews: