![Wire wizard EL-NCS-20 Installation & Operation Manual Download Page 7](http://html.mh-extra.com/html/wire-wizard/el-ncs-20/el-ncs-20_installation-and-operation-manual_988435007.webp)
5
TORCH WIZARD INSTALLATION & OPERATION MANUAL
wire-wizard.com
2.4 ADJUSTING THE V-BLOCK
The Torch Wizard® Nozzle Cleaning Station incorporates an adjustable V-Block feature. This feature eliminates the need to
replace the V-Block when changing to different diameter gas nozzles. To adjust the V-Block, follow the procedure below (along
with Figs. 4 and 5).
Ensure that there is no air pressure or electrical power to the unit before performing this procedure.
1. Open the Stainless Steel Guard (2) by unlocking the latch.
2. Install the reamer blade (7). Use the slim profile wrench provided to hold the
motor in place when securing the reamer blade.
3. Loosen Set Screw (3).
4. Loosen the Low Head Socket Head Cap Screw in the clamp (4).
5. Adjust the V-Block (6) using the Adjuster Screw (5) so that when the air motor
is at its upper point, the reamer is centered in the gas nozzle. To check this,
hold a gas nozzle in V-Block and raise the air motor slide by hand.
6. Tighten Low Head Socket Head Cap Screw (4).
7. Tighten Set Screw (3).
8. Replace the Stainless Steel Guard and Catch Tray (2) and tighten screws, or leave open if performing the initial setup
and proceed to reamer adjustment.
Figure 5
2
1
6
5
3
4
Figure 4
7
The graphic above represents the approximate location
of the V-Block when set up for a gas nozzle with a 1 inch
outside diameter.