7. To assemble the gland assembly, insert the inside T-seal and wiper, again using Vaseline on the T-seal.
a. The gland must be installed from the end-cap side (this is the side without the holes).
b. Lube the outside of the inner cylinder with hydraulic fluid for ease of assembly.
c. Install the T-seal into the end-cap, again using Vaseline for lube.
d. Install the inner cylinder into the end-cap (the end of the tube without holes).
8. For piston install, place the piston onto the metering tube using hydraulic fluid for lube to prevent damage to
the threads.
a. Using a spanner wrench, tighten the piston to the inner cylinder.
b. Install the jam nut onto the piston end of the metering tube and stake for security.
c. Install the 2 T-seals onto the exterior of the piston and gland, and lube with Vaseline.