SERVICE MANUAL & ICA
8750 AMPHIBIAN/SEAPLANE FLOATS ON CESSNA 208/208B
P/N 1005723 Doc. No. W8750-24-01
Page 68 of 104
Revision C
FIGURE 5-1: HYDRAULIC SCHEMATIC
HYDRAULIC RAMS
LOCATED IN
FLOATS
UNION FITTINGS
FOR WHEEL/FLOAT
SWAP
DUAL DIRECTION PUMP
INTERNAL SHUTTLE VALVE
WITH 1150 /- 150 PSI
1400 PSI THERMAL RELIEF
UP AND DOWN
PREASURE SWITCHES
FOR EACH PUMP
UP 500-1000 PSI
DOWN 500-700 PSI
AFT FUSELAGE
MOUNTED
POWER PACK WITH
PUMPS, PREASURE
SWITHCES AND
CHECK VALVES.
CROSS FITTINGS
LOWER FUSELAGE
EMERGENCY
HAND PUMP
IN CABIN
A
RET
DN
NOSE GEAR RAMS
W/POSITION
SWITCHES
UP
DOWN
UP
DOWN
DOWN
UP
DOWN
UP
MAIN GEAR RAMS
W/PROXIMITY
SWITCHES
RET
UP
DN
UP
RET
S
B