tube heater and fiber protection sleeve are hot and should
not be touched. Possible burn may result.
26
.
Replace the electrodes properly.
·
Use only specified electrodes.
·
Set the new electrodes in the correct position.
·
Replace the electrodes as a pair.
Disregard of the above instructions may cause abnormal arc discharge and
result in equipment damage or degradation in splicing performance.
27
.
The equipment must be repaired or adjusted by a qualified technician
or engineer. Incorrect repairs may cause fire or electric shock.
Should any problem arise, please contact your nearest sales agency.
§
2.Description
§
2
.
1
.
Specification
Applicable Fiber
Single mode and multi mode silica based
optical glass fiber
·
Cladding diameter
:
100
–
150um
·
Coating diameter
:
0.1-1.0mm
1
Cleave Length
Standard spec
:
16mm
Mean Splice Loss
(Note 1)
·
Single mode fiber
:
Typ.0.02dB
·
Dispersion shifted fiber
:
Typ.0.04dB
·
Multi mode fiber
:
Typ.0.01 dB
Mean Splice Time
(Note 2)
Typ. 8 seconds
2
Fiber Protection
Sleeve Shrinking
Time (Note 3)
40mm
/
60mm sleeve
:
Typ.40seconds
Dimensions
170mm(W)
/
170mm
(
D
)/
145mm(H)
3
Weight
4.1 kg
4
Battery/Charger
WY-725-01 with battery charge function
·
Input power
:
85
~
264 V
(
47
~
63HZ
)
·
Output power
:
9
~
3V
,
10Ah
5
Proof Test Force
·
Standard spec.
:
Approx.1.96N
(
200gf
)
Page 5