WPC 1000 User Manual
1125100
Installation
2-23
Mounting the Resolver
To mount the resolver, perform the following steps:
1.
Mount the resolver by bolting it to the press or other platform at the desired location.
2.
Make sure the press is at TDC.
3.
Rotate the resolver shaft so that the keyway is aligned with the arrow on the housing (see
Figure 2-13).
Figure 2-13. Resolver: Mounting Dimensions
It does not matter which direction the resolver turns when the press runs. You adjust for the
direction of rotation when you wire the unit (see Wiring the Resolver, next section).
2.75
(69.9)
1.06
(26.9)
1.75
(44.5)
2.00
(50.8)
3/4 dia. shaft (19.05)
standard key
Electrical connector
for cable
3.62
(91.9)
0.34 (8.6) dia holes
2 places
9.16
(232.7)
RESOLVER IS AT ZERO WHEN
KEYWAY IS ALIGNED WITH ARROW
3.00
(76.2)
3.75
(95.3)
1.50
(38.1)
Resolver shown in
zero-degrees position,
with key perpendicular
to base
Dimensions: inches
(mm)
NOTICE