11
Gear Reservoir Oil Change
Before installation/maintenance, ensure both tractor and
attachment are stationary, with the hydraulic lift system in a neutral
position and the ignition key removed.
Ensure the reservoir has sufficient oil to allow grease to the lower gear,
which will then work its way up the gears when operating. Do not mix old
and new oils together, or mix different oil types. Always dispose of oils
correctly and safely.
After use, the attachment should be left to cool down for 15 minutes
before checking oil levels. Ensure the gearbox is flat/level when checking
oil levels. Always follow manufacturer
’
s instructions for oils and lubricants.
Gear Reservoir Oil Grade:
SAE140 gear oil (or equivalent) by condition
Reservoir Oil Level:
Approx. 2 litres
First Oil Change
50 hours use
Oil Change Frequency
250 hours/yearly (whichever is first)
4
5
Remove breather/filler plug (
4
) and drain plug (
5
) to allow the oil to drain
from the reservoir. Replace and screw in drain plug (
5
), replace oil using a
funnel through filler hole (
4
). Replace breather/filler plug (
4
).
12
Rear Guard Adjustment
Before installation/maintenance, ensure both tractor and
attachment are stationary, with the hydraulic lift system in a neutral
position and the ignition key removed.
To determine how compacted the soil is after cultivating, adjust the rear
guard using an adjustment rod. The rod is sprung so there is downwards
force on the rear panel to aid compaction.
Remove R clips (
1
) and (2). Move both R clip 1 up or down and insert into
one of the holes (
3
). Move R clip (
2
) up or down the same number of holes
into (
4
). Ensure the springs remain between the two R clips.