Handleiding GA3911 Smart Box ECO Heater v02.doc 

Version: 0.2      

 

2014-02-26 

 

1/8

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Version: 0.2      

26 February 2014  

 
 

 

SmartBox ECO Heater 

GA3911 

 

Summary of Contents for SmartBox ECO Heater

Page 1: ...Handleiding GA3911 Smart Box ECO Heater v02 doc Version 0 2 2014 02 26 1 8 Version 0 2 26 February 2014 SmartBox ECO Heater GA3911 ...

Page 2: ...overview 3 1 1 Buttons 3 1 2 Display icons 3 2 Status screen 4 2 1 Startup 4 2 2 No communication 4 3 Demand generation 5 3 1 Manual heat demand 5 3 2 Manual ventilation demand 5 4 Extra information 6 4 1 Flamerod menu 6 4 2 History menu 6 4 2 1 Locking errors 6 4 2 2 Blocking errors 6 4 2 3 Error codes 7 4 3 Settings menu 8 ...

Page 3: ...uttons is shown in Figure 1 166RT SmartBox Their respective function are shown in Table 1 Button functions 1 2 Display icons The display is able to show icons that give a better view on the current status of the system In Table 2 Display icons the icons that can be displayed with the status of the system Icon Status System is burning System is ventilating System is in error Button Function S1 Heat...

Page 4: ...7 Heat demand Burn on ignition speed H 8 Heat demand Burn on maximal speed H 9 Heat demand Post purge A X Y Locking error XY is the error code see chapter E X Y Blocking error XY is the error code see chapter 2 1 Startup During startup of the SmartBox the display shows This means that the SmartBox did not receive any bytes over the communication 2 2 No communication When the communication is lost ...

Page 5: ...heat demand is send to the main control During the heat demand the display shows the actual status of the system To stop the demand the button Auto Off needs to be pressed 3 2 Manual ventilation demand To generate a manual ventilation demand the Heat Fan button needs to be pressed until the display shows the text FAn For this the button needs to be pressed at least 5 seconds After the button is re...

Page 6: ...display shows the status 0 To enter the locking menu buttons Plus and Reset Menu have to be pressed simultaneously for 3 seconds The first character on the display now shows the index number of the error The other 2 characters on the display alternately show A and the error code By pressing buttons Plus or Min it is possible to navigate through the last 9 locking errors To exit the menu the button...

Page 7: ... on the display The left character shows the state of the control in which the error was stored The right character shows on of the following error codes Error code Details 0 Internal error 1 Transport fan air switch error 2 Burner fan air switch error 3 Flame detection error 4 Too high gas pressure 5 Too low gas pressure 6 Too low supply voltage 7 Not used 8 Overheat Table 4 Error codes ...

Page 8: ...y shows the status 0 To enter the settings menu the buttons Reset Menu has to be pressed for 3 seconds By pressing buttons Plus or Min it is possible to navigate through the menu Settings can be changed by pressing the Reset Menu button for 3 seconds The setting will start blinking When the setting is blinking the setting can be changed with the buttons Plus or Min The image below shows the menus ...