Handleiding GA3911 Smart Box ECO Heater v02.doc
Version: 0.2
2014-02-26
4/8
2
Status screen.
The SmartBox is able to display the status of the system. The status is shown with a status ID
and 2 status codes.
Status ID
Code left
Code right
Status
-
0
Off.
S
0
Standby, no demand.
F
0
Ventilation demand.
H
1
Heat demand (Pre purge 0)
H
2
Heat demand (Pre purge 1)
H
3
Heat demand (Pre purge 2)
H
4
Heat demand (Pre purge 3)
H
5
Heat demand (Ignit 0)
H
6
Heat demand (Ignit 1)
H
7
Heat demand (Burn on ignition speed)
H
8
Heat demand (Burn on maximal speed)
H
9
Heat demand (Post purge)
A
X
Y
Locking error (XY is the error code, see chapter….)
E
X
Y
Blocking error (XY is the error code, see chapter….)
2.1
Startup
During startup of the SmartBox the display shows ‘---’. This means that the SmartBox did not
receive any bytes over the communication.
2.2
No communication
When the communication is lost for 10 seconds the display will show the text ‘no’/’conn’.
This means that the SmartBox isn’t able to start communication or the data is corrupted.
When the communication is restored the message is cleared and the normal status is
displayed.
Table 3 – Status display