6
3.2.2 Natural gas G25
Specification
Unit
Natural gas G25.3 (NL)
Natural gas G25 (BE/DE/FR)
Nominal supply pressure
mbar
25
Supply pressure (min. - max.)
mbar
20-30
Gas category
-
NL: II
2
EK
3
B/P
DE: II
2
ELL
3
B/P
BE: I
2
Er
FR: II
2
Er
3
B/P
Class
-
A3
Specification
Unit
DXA75
DXA100
DXA120
Gas consumption
m
3
/h
8.9
11.8
14.2
Burner injectors
n x Ømm
1x 8.5
1x 10.5
1x 12.0
Burner pressure
mbar
11.5
9.5
10.0
3.2.3 Butane / LPG G30
Specification
Unit
Butane / LPG G30
Nominal supply pressure
mbar
30 / 50
Supply pressure (min. - max.)
mbar
20-50
Gas category
-
II
2
H
3
P B/P
NL: II
2
EK
3
B/P
DE: II
2
ELL
3
B/P
BE: I
3
B/P
FR: II
2
Er
3
B/P
PL: II
2
ELwLs
3
B/P
Class
-
A3
Specification
Unit
DXA75
DXA100
DXA120
Gas consumption
kg/h
6.0
8.0
9.5
Burner injectors
n x Ømm
1x 5.85
1x 6.85
1x 7.8
Burner pressure
mbar
10.0
10.0
8.8
Summary of Contents for DXA100