Please ensure that the mounting thread is clean and free of damage.

-

Check to ensure that the O-ring fits properly in the groove.

-

Screw in the mounting thread of the transmitter in the transmitter flange.

-

Next, tighten it by an open-end wrench. (approx. 25 Nm)

-

Install the flange according to your demands. If a new transmitter flange is needed, it can be ordered from 
Winters Instruments

Removing the protection cap (if existing)

For the protection of the diaphragm, some of the probes have a plugged-on protection cap. If the device shall be
used in high-viscosity media such as sludge, a removal of the cap before start-up is necessary. Thus, the sensor
becomes flush and the medium will attain quickly to the diaphragm.

If it is necessary for your application to remove the protection cap, this has to be done with utmost care. To 
prevent a damage of the diaphragm, please follow these instructions.

Removal by hand

-

Hold the probe in a way that the protection cap points upwards.

-

Hold the probe with one hand on the sensor section (1).

-

Remove the protection cap (2) with the other hand.

Removal with a tool (recommended)

-

Hold the probe in a way that the protection cap points upwards.

-

Slide a small tool such as a screwdriver (8) straight through two opposite drill holes in the protective cap (2).

-

Lever it off by moving up the handle of the screwdriver.

Make sure that the sensor (7) under the protection cap will not be damaged!

3.5 Cable protection (optional)

On order, the probe has been delivered with cable protection; if the device has optionally been prepared for
mounting with stainless steel or PVC pipe, a suitable cable protection has to be mounted by the customer.

The probe must be installed in such a way that rubbing or impact of the device, e. g. against a tank wall, is 
prevented. It is also important to consider the operating conditions such as flow conditions.

Electrical Installation

Y WARNING!

Install the device only when currentless!

Establish the electrical connection of the device according to the technical data shown on the manufacturing label,
the following table and the wiring diagram.

Y    DANGER!

   The transmitter must not be installed in potentially explosive atmosphere requiring category 1 status.

Y    WARNING!

 Input supply to pressure transmitter must be SELV (or class 2). Source in accordance with CSA 

61010-1-04.

 

 

 

figure 2

removal of protection cap

Summary of Contents for LM7 Series

Page 1: ...www winters com WINTERS INSTRUMENTS MANUFACTURER OF INDUSTRIAL INSTRUMENTATION LM7 SUBMERSIBLE TRANSMITTER INSTALLATION AND OPERATING MANUAL...

Page 2: ...pply 0 05 FSO 10 V Load 0 05 FSO kOhm Response Time 10 msec Thermal Error 0 2 FSO 10K Permissible Temperatures Medium 14 F to 158 F 10 C to 70 C Storage 13 F to 158 F 25 C to 70 C Short Circuit Protec...

Page 3: ...entially dangerous situation which may result in minor injuries CAUTION potentially dangerous situation which may result in physical damage NOTE tips and information to ensure a failure free operation...

Page 4: ...Handle this high sensitive electronic precision measuring device with care both in packed and unpacked condition There are no modifications changes to be made on the device Do not throw the package de...

Page 5: ...sor section 1 Remove the protection cap 2 with the other hand Removal with a tool recommended Hold the probe in a way that the protection cap points upwards Slide a small tool such as a screwdriver 8...

Page 6: ...ould cause problems this cable has to be checked with the following calculation with RL resistance of connecting cable in ohm p specific resistance in ohm mm m l cable length in m A cross section of c...

Page 7: ...who have read and understood the operating manual Y WARNING The device has to be used within the technical specifications only compare the data in the data sheet Placing out of service Y WARNING When...

Page 8: ...indicating the RMA Disposal The device must be disposed according to the European Directives 2002 96 EG and 2003 108 EG on waste electrical and electronic equipment Waste of electrical and electronic...

Page 9: ...WINTERS INSTRUMENTS Tel 1 800 WINTERS www winters com 9...

Page 10: ...NTERS Fax 403 723 6647 calgary winters com USA Houston Winters Instruments 5400 W Sam Houston Pkwy N Houston Texas 77041 Tel 281 880 8607 1 800 WINTERS Fax 281 880 8614 usasales winters com Asia Shang...

Reviews: