SECTION 10 –
SLIDEOUT ROOMS AND LEVELING
10-6
SLIDEOUT ROOM
TROUBLESHOOTING –
ELECTRIC
Battery Voltage or Circuit Breaker
Problems
If the slideout room will not work:
•
Turn the Chassis Battery Disconnect switch
OFF and then ON again. This will (in many
cases) reset power to the slideout system.
•
Τ
he chassis battery may be low on charge.
Press and hold the Battery Boost switch on the
dash while pressing the slideout control
switch. This momentarily connects the house
batteries to assist in slideout room operation.
•
The circuit breaker may be tripped. The
circuit breaker, labeled “Slideout Power” is
located on a panel on an interior wall of the
passenger side storage compartment just
behind or ahead of the entrance door.
Problems Retracting the Room
•
Set the Park Brake if the Engage Park Brake
light flashes while pressing the Retract (IN)
button.
If an error is detected on your slide system, the
LED light on the control panel will blink an error
code. If an error code appears, see the
manufacturer’s user guide in your InfoCase to
determine the problem. The error code must be
cleared prior to operating the room. To clear the
error and reset the system:
•
If none of the “Battery Voltage or Circuit
Breaker Problems” troubleshooting
recommendations reset the system, remove
the touchpad from the monitor panel (a
screwdriver will be needed) and press and
hold the RESET button (“Set Stops/Clear
Fault”) located on the back of the touchpad for
5 seconds. The slideout is now ready to be
retracted. Press IN on the touchpad to retract
the room.
•
Reinstall touchpad to the wall.
•
Take your vehicle to an authorized service
center for repair.
Before operating the room after an error has
been detected, check for obvious faults such as
obstructions prior to trying to operate the room
again. If the error code appears again, the room
will need to be retracted using either the manual
retraction method or the fully manual method.
Both methods listed below are intended as a
means to retract the room to prepare the coach for
travel to the nearest authorized service center.
Manual Mode
Manual Mode lets you individually move the
two room arms by pressing the IN and OUT
buttons on the touchpad.
This mode can be used
only if there is not a motor failure or full
electrical system failure.
To override the encoder
and enter the Manual Mode, press and hold the
RESET button (“Set Stops/Clear Fault”) located
on the back of the touchpad until the two LEDs
begin to flash.
While in the Manual Mode, each of the two
room slide arms are activated by pressing and
holding the IN and OUT buttons. The “OUT”
button will retract the front arm. The “IN” button
will retract the back arm. Both IN and OUT
buttons may be held down at the same time to
simultaneously activate both arms to retract the
room. If one side of the room gets ahead of the
other, release that button until the other arm
• Light will flash fault
code if system
malfunctions
• Light will flash if
park brake not set
• Low Voltage
Indicator
Slideout Touchpad
(Located near monitor panel)
-Typical View