background image

3. ASSEMBLY CONDITIONS 

 

Only WINNCARE beds listed below are compatible with SAMs :

 

 

Bed 

reference 

SAMs reference 

Bed reference 

SAMs reference 

IAL1L* 

A614/A615-00   A618/A619-00 

A628/A629-00 

IEX1L 

A614/A615-00   A618/A619-00 A628/A629-

00 

IAL2L* 

A614/A615-00   A618/A619-00 

A628/A629-00 

IEX2L 

A614/A615-00   A618/A619-00 A628/A629-

00 

IAL3L* 

A614/A615-00   A618/A619-00 

A628/A629-00 

IEX3L 

A614/A615-00   A618/A619-00 A628/A629-

00 

IAL4L* 

A614/A615-00   A618/A619-00 

A628/A629-00 

IEX4L 

A614/A615-00   A618/A619-00 A628/A629-

00 

IAL5L / AL5* 

A647/A648-00   A649/A650-00 

A651/A652-00 

IEX5L 

A647/A648-00   A649/A650-00 A651/A652-

00 

IXS1L 

A614/A615-00   A618/A619-00 

A628/A629-00 

IMS1L 

A614/A615-00   A618/A619-00 A628/A629-

00 

IXS2L 

A614/A615-00   A618/A619-00 

A628/A629-00 

IMS2L 

A614/A615-00   A618/A619-00 A628/A629-

00 

IXS3L 

A614/A615-00   A618/A619-00 

A628/A629-00 

IMS3L / MS3 

A647/A648-00   A649/A650-00 A651/A652-

00 

IXP1L 

A614/A615-00   A618/A619-00 

A628/A629-00 

IML1L 

A614/A615-00   A618/A619-00 A628/A629-

00 

IXP2L 

A614/A615-00   A618/A619-00 

A628/A629-00 

IML2L / ML2 

A647/A648-00   A649/A650-00 A651/A652-

00 

IXP3L 

A614/A615-00   A618/A619-00 

A628/A629-00 

IAE1L 

A614/A615-00   A618/A619-00 A628/A629-

00 

IXP4L 

A647/A648-00   A649/A650-00 

A651/A652-00 

IAE2L / AE2 

A647/A648-00   A649/A650-00 A651/A652-

00 

IXX1L 

A614/A615-00   A618/A619-00 

A628/A629-00 

IAE3L / AE3 

A647/A648-00   A649/A650-00 A651/A652-

00 

IXX2L 

A614/A615-00   A618/A619-00 

A628/A629-00 

IAF1L / AF1 

A647/A648-00   A649/A650-00 A651/A652-

00 

IXX3L 

A647/A648-00   A649/A650-00 

A651/A652-00 

IAF2L / AF2 

A647/A648-00   A649/A650-00 A651/A652-

00 

IXA1L / XA1 

A647/A648-00   A649/A650-00 

A651/A652-00 

IAX1L / AX1 

A647/A648-00   A649/A650-00 A651/A652-

00 

IXB1L / XB1 

A647/A648-00   A649/A650-00 

A651/A652-00 

IDO1L 

A614/A615-00   A618/A619-00 A628/A629-

00 

IXL1L 

A614/A615-00   A618/A619-00 

A628/A629-00 

IDO2L 

A614/A615-00   A618/A619-00 A628/A629-

00 

IXL2L 

A614/A615-00   A618/A619-00 

A628/A629-00 

IDO3L 

A614/A615-00   A618/A619-00 A628/A629-

00 

IXL3L 

A614/A615-00   A618/A619-00 

A628/A629-00 

IDO4L 

A614/A615-00   A618/A619-00 A628/A629-

00 

IXL4L 

A647/A648-00   A649/A650-00 

A651/A652-00 

IDO5L 

A647/A648-00   A649/A650-00 A651/A652-

00 

IXN1L / XN1 

A647/A648-00   A649/A650-00 

A651/A652-00 

IDO6L 

A647/A648-00   A649/A650-00 A651/A652-

00 

IXO1L 

A614/A615-00   A618/A619-00 

A628/A629-00 

IDO7L 

A647/A648-00   A649/A650-00 A651/A652-

00 

IXO2L 

A614/A615-00   A618/A619-00 

A628/A629-00 

IDO8L / DO8 

A647/A648-00   A649/A650-00 A651/A652-

00 

IXO3L / XO3 

A647/A648-00   A649/A650-00 

A651/A652-00 

 

 

 if height less than 240 mm

 

 
 MSSs are delivered folded up. 
 
 
 
 

 

 

Summary of Contents for SAM Ergonom A618-00

Page 1: ...2 51 98 59 07 Email info medicatlantic fr Site Internet http www winncare fr USER S MANUAL Mobility Support Systems A649 00 A650 00 SAM Ergonom A647 00 A648 00 SAM Ergonom plus A651 00 A652 00 SAM Erg...

Page 2: ...S A647 00 A648 00 A649 00 A650 00 A651 00 A652 00 6 4 CONDITIONS FOR USE 7 4 1 FUNCTION 7 4 2 USE 8 4 3 PRECAUTIONS FOR USE 9 4 4 RESIDUAL RISKS 9 5 MAINTENANCE CONDITIONS 9 5 1 IDENTIFICATION 9 5 2 U...

Page 3: ...nsure you maximum safety and performance As a result maintenance of the contracted good s warranty depends on compliance with the conditions for use recommended by WINNCARE and the use of original boa...

Page 4: ...0 A628 A629 00 IXP4L A647 A648 00 A649 A650 00 A651 A652 00 IAE2L AE2 A647 A648 00 A649 A650 00 A651 A652 00 IXX1L A614 A615 00 A618 A619 00 A628 A629 00 IAE3L AE3 A647 A648 00 A649 A650 00 A651 A652...

Page 5: ...the grip jaws Position the grip jaws as shown in the diagrams below In order to assemble them on the bed the longest section on the head end must be positioned by tightening the two adjustment knobs u...

Page 6: ...oning the nut on the inner side of the bed 3 Screw the jaw with the screw and nut provided with an Allen wrench n 4 Insert pole of the side rail in the jaw on the head side fixed on the bed until to h...

Page 7: ...t should preferably be carried out of the mobility support system to decide whether or not to use it This assessment must take the following into account the department s surveillance capacities A sta...

Page 8: ...site the SAM to move towards the exit of the bed when you pull toward you with your arms the handle of the SAM The turning handle is raised only when the barrier is folded back It allows the patient t...

Page 9: ...ake sure not to rub the side handle along vertical walls When the bed is placed in low position ensure that nothing or no area of the patient s or carer s body is between the bed boards accessories an...

Page 10: ...neat Persistence time must be applied according to the disinfectant manufacturer drying time often equals the persistence time excluding human presence SANIVAP type steam device with accessories 5 4...

Page 11: ...protect the disinfected equipment from other equipment that has not been disinfected by a film and a label indicating the disinfection date 5 5 Lifetime The lifetime under normal conditions of use an...

Page 12: ...12...

Reviews: