A detailed examination must be carried out on the side rails at least once a year on such parts as : cross-beam 
guides, cross-beams and unlocking fingers. 
 

 

5.3. Cleaning 

 
High pressure cleaning, machine cleaning, washing tunnel or jet cleaning is prohibited. 
 
Clean  the  structure  with  soapy  water  and  a  soft  cloth  then  rinse  and  wipe  dry.  All  aggressive  or  scouring 
products such as detergents, powders, solvents and bleach are prohibited. 
 

5.4. Disinfection 

 
Isolate the side rails in a disinfection room equipped with a particle filtering system and disposal for washing 
the floors and walls after disinfection. 
Use  a  disinfectant  with  bactericidal,  fungicidal  and  virucidal  properties,  either  by  spraying  it  evenly  onto 
surfaces, applying it with a disposable cloth or spraying a disinfectant aerosol from a distance of 30 cm. 
 

NB: 

 
Comply with the precautions for using disinfectants indicated on these products. 
Leavy to dry and protect the disinfected equipment from other equipment that has not been disinfected by a 
film and a label indicating the disinfection date. 
 
 
 

5.5. Lifetime 

 
The lifetime under normal conditions of use and maintenance is 5 years for accessories, especially for wooden 
side rails. 
 

5.6. Warranties 

 

 

All of our products carry a warranty against any manufacturing defect, provided the normal conditions 

for use and maintenance are complied with. 
 

 

Labour costs due to changes in structures or parts under warranty are not taken into account. 

 

 

Please refer to the standard terms of sale for the specific terms of warranty for each product. 

 

 

Every  time  you  contact  us  for  possible  maintenance,  you  must  quote  us  the  information  on  the 

identification label located under the cross-beam. 
 

 

Original  parts  shall  be  supplied  for  replacement,  within  the  term  of  warranty,  by  our  customer  sales 

network determining the beginning of the term of warranty. 
 

 

Defective parts must be returned to ensure proper application of this warranty and also to avoid any 

invoicing. 
 

6. CONDITIONS FOR SCRAPPING 

 

 

The product must be scrapped if the main requirements are no longer met, particularly when the product 

no longer has its original characteristics and has not been subject to corrective action during the manufacturing 
process. 
 

 

Measures should therefore be taken to ensure that the product is no longer used for the purpose it was 

originally intended. 
 

 

When scrapping, the current environmental standards must be complied with. 

 

 

Summary of Contents for A579-00

Page 1: ...Le Pas du Ch teau 85670 SAINT PAUL MONT PENIT TEL 33 0 2 51 98 55 64 FAX 33 0 2 51 98 59 07 Email info medicatlantic fr Site Internet https www winncare fr USER S MANUAL WOODEN BARRIERS A579 00 A580...

Page 2: ...Regulation EU 2017 745 relating to medical devices They are tested in conformity with standard EN 60601 2 52 2010 in their commercial configurations including the boards and accessories that we manufa...

Page 3: ...nt falls BUT it can pose a hazard injuries falling after trapping a limb in the side rails suffocation after trapping the head neck or chest A risk benefit assessment should preferably be carried out...

Page 4: ...that have panels with recesses needed for their assembly and that are not equipped with bed frame extensions The barrier has been tested in accordance with the test method of standards NF EN 50637 an...

Page 5: ...n in the low cross bar guide The assembly is identical for all full length wooden barriers and only the barrier of the A680 00 junior bed is composed of a low wood metal cross member to respect the st...

Page 6: ...6 The element composed of the wood and metal bar is always placed in the lower part The arrow down and to the inside of the bed 5...

Page 7: ...7 6 8 7 9 10...

Page 8: ...rrier To lower the side rail Take the upper bar and lift it up to its locking at the top of the panel Check if it is properly engaged To lower the side rail 1 l Lift the upper bar 2 Press the locking...

Page 9: ...ier gently down the bed make sure that no objects or parts of the patient s body or nursing staff are in the operating area until the stop is stopped The upper bar comes to rest on the lower metal woo...

Page 10: ...g used Side rails are a medical device and in this regard we inform you that it must not be modified under any circumstances You must ensure its traceability If you assemble different types of medical...

Page 11: ...itions of use and maintenance is 5 years for accessories especially for wooden side rails 5 6 Warranties All of our products carry a warranty against any manufacturing defect provided the normal condi...

Page 12: ...12...

Reviews: