background image

 

- 20 - 

3 INSTALLATION 

3.1 Wiring Requirements 

The following common safety precautions should be observed before 
installing any electronic device:  

  Strive  to  use  separate,  non-intersecting  paths  to  route  power 

and  networking  wires.  If  power  wiring  and  device  wiring  paths 
must  cross  make  sure  the  wires  are  perpendicular  at  the 
intersection point.  

  Keep  the  wires  separated  according  to  interface.  The  rule  of 

thumb is that wiring that shares similar electrical characteristics 
may be bundled together.  

  Do  not  bundle  input  wiring  with  output  wiring.  Keep  them 

separate.  

  When  necessary,  it  is  strongly  advised  that  you  label  wiring  to 

all devices in the system. 

 

 

CAUTION 

  Do not run signal or communication wiring and power wiring in 

the same conduit. To avoid interference, wires with different 
signal characteristics (i.e., different interfaces) should be routed 
separately.  

  Be sure to disconnect the power cord before installing and/or 

wiring your device.  

  Verify the maximum possible current for each wire gauge, 

especially for the power cords. Observe all electrical codes 
dictating the maximum current allowable for each wire gauge.  

  If the current goes above the maximum ratings, the wiring could 

overheat, causing serious damage to your equipment.  

  Be careful when handling the unit. When the unit is plugged in, 

the internal components generate a lot of heat which may leave 
the outer casing too hot to touch. 

 

Summary of Contents for W07IB3S-EHT1

Page 1: ...this manual for future use E Series HMI Intel Celeron Bay Trail M N2930 1 83 GHz W07IB3S EHT1 W10IB3S EHH2 W15IB3S EHA2 Quick Start Guide V1 1 For more information on this and other Winmate products p...

Page 2: ...tor 14 2 2 2 Serial Port Connector 14 2 2 3 Ethernet Connector 15 2 2 4 USB Connector 15 2 2 5 HDMI Connector 16 2 3 Changing Serial Port Settings 17 2 4 How to Enable Watchdog 18 2 5 Turning off Your...

Page 3: ...ice pursuant to part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipme...

Page 4: ...000 4 5 2014 o IEC61000 4 6 2014 o IEC61000 4 8 2010 o IEC61000 4 11 2004 EN55032 2012 AC 2013 EN61000 3 2 2014 EN61000 3 3 2013 Low Voltage Directive 2014 35 EU EN 60950 1 2006 A11 2009 A1 2010 A12 2...

Page 5: ...that are described in this manual are for illustration purposes only We make no representation or guarantee that such application will be suitable for the specified use without further testing or mod...

Page 6: ...ical support if you need additional assistance You may need the following information ready before you call Product serial number Software OS version application software etc Description of complete p...

Page 7: ...ent devrait ouvrir ces chassis CAUTION ATTENTION Always ground yourself to remove any static charge before touching the CPU card Modern electronic devices are very sensitive to static electric charges...

Page 8: ...mounting there is no need to drill holes in a fixture This saves you the time for mounting and guarantee aesthetic look of the wall after the unit gets removed 1 1 Features Winmate E Series HMI featur...

Page 9: ...ckage If any of these items are missing or damaged contact us immediately Standard factory shipment list HMI Device Quick Start Guide Hardcopy Driver CD SBC User Manual Varies by product specification...

Page 10: ...10 1 3 Product Overview 1 3 1 E Series HMI 7 Unit mm Description Description 12V DC Power Jack HDMI 1 4a RS 232 422 485 RJ 45 Gbe LAN x 2 USB 3 0 x 1 USB 2 0 x 1...

Page 11: ...11 1 3 2 E Series HMI 10 1 Unit mm Description Description 12V DC Power Jack HDMI 1 4a RS 232 422 485 RJ 45 Gbe LAN x 2 USB 3 0 x 1 USB 2 0 x 1...

Page 12: ...12 1 3 3 E Series HMI 15 6 Unit mm Description Description 12V DC Power Jack HDMI 1 4a RS 232 422 485 RJ 45 Gbe LAN x 2 USB 3 0 x 1 USB 2 0 x 1...

Page 13: ...n jack connector on the back side of the HMI device 2 Connect the power cord to AC adapter 3 Plug the power cord to the AC outlet and the device will turn on automatically ALTERNATING CURRENT This pro...

Page 14: ...r HMI to external devices such as mouse modem or printer Refer to Configuring Serial Port Settings of this Quick Start Guide for more detail Pin Signal Name Pin Signal Name 1 DC_IN 2 GND Voltage Minim...

Page 15: ...ctor E Series HMI has USB 2 0 and USB 3 0 connectors Use USB cable to connect the HMI to other external devices such as a keyboard or mouse Pin Signal Name Pin Signal Name 1 TX1 2 TX1 3 TX2 4 TX2 5 TX...

Page 16: ...connect to the external display Pin Signal Name Pin Signal Name 1 TMDS_DATA2 2 GND 3 TMDS_DATA2 4 TMDS_DATA1 5 GND 6 TMDS_DATA1 7 TMDS_DATA0 8 GND 9 TMDS_DATA0 10 TMDS_CLOCK 11 GND 12 TMDS_CLOCK 13 CE...

Page 17: ...may be helpful when working with jumpers If you have any doubts about the best hardware configuration for your application contact your local distributor or sales representative before you make any c...

Page 18: ...re information on Watchdog in Watchdog Guide that you can download from Winmate Download Center or File Share To enable watchdog in Watchdog AP follow the instructions below 1 On the right bottom side...

Page 19: ...s 0 Every 9 min watchdog timer will be reset to 10 min Settings Description Watchdog Countdown Time The system automaticity restarts when this countdown time reaches zero Default 10 min Periodically F...

Page 20: ...sed that you label wiring to all devices in the system CAUTION Do not run signal or communication wiring and power wiring in the same conduit To avoid interference wires with different signal characte...

Page 21: ...aking the HMI unit easy to clean and maintain The HMI device is secured to the fixture from the rear by using the mounting brackets included in the package Cutout dimension W x D in mm 7 10 1 15 6 179...

Page 22: ...ESA mounting solution applies only to 7 E Series HMI Notice that VESA mounting kit is not supplied by Winmate Dimensions Screw Hole Diameter 75 x 75 mm VESA M4 x 3 mm Mounting Instruction 1 Screw VESA...

Page 23: ...ications Dimensions mm W x H x D 184 94 x 127 7 x 44 9 267 42 x 182 14x 57 6 421 x 260 6 x 65 5 Mounting 4 x Mounting clips VESA Mounting 75x75mm 8 x Mounting clips 10 x Mounting clips Cooling Fanless...

Page 24: ...tandard Windows Embedded Standard 7 Input Output USB Port 1 x USB 2 0 1 x USB 3 0 COM Port 1 x RS232 422 485 Ethernet 2 x RJ45 10 100 1000 HDMI 1 x HDMI 1 4a Environment Considerations Operating Tempe...

Page 25: ...play area is highly prone to scratching Do not use ketene type material ex Acetone Ethyl alcohol toluene ethyl acid or Methyl chloride to clear the panel It may permanently damage the panel and void t...

Page 26: ...1 SDK Watchdog SDK 2 Utility Watchdog Utility To find the Drivers and SDK please refer to the Driver CD that comes in the package or contact us Also you can download drivers from Winmate Download Cen...

Page 27: ...______________________________________________ _______________________________________________________ _______________________________________________________ _________________________________________...

Page 28: ...Winmate Inc 9F No 111 6 Shing De Rd San Chung District New Taipei City 24158 Taiwan R O C Tel 886 2 8511 0288 Fax 886 2 8511 0211 Email sales winmate com tw Official website www winmate com...