3. In Watchdog utility window set countdown time and periodically
feed time, or disable watchdog.
Example:
Every 10 min watchdog will
monitor the system, in case
any error occurs the system
will restart automatically when
the countdown time reaches 0.
Every 9 min watchdog timer
will be reset to 10 min.
Settings
Description
Watchdog Countdown
Time
The system automaticity restarts
when this countdown time reaches
zero
.
Default: 10 min
Periodically Feed Time
To set a cycle time to automatically
reset watchdog timer.
Default: 9 min
Enable / Disable
Enable or disable watchdog.
Default:
Enable
2.5 Turning off Your Device
Disconnect the power cord from the HMI device to completely turn off