background image

 

About This User Manual 

About This User Manual 

This User Manual provides information about using the IBDRW100-P Series DIN Rail Box PC. 
This  User  Manual  applies  to  the  IBDRW100-P  Series  DIN  Rail  Box  PC  -  IBDRW100-P/ 
IBDRW100-EX-P. 

The documentation set for the IBDRW100-P Series DIN Rail Box PC provides information for 
specific user needs, and includes: 

 

User  Manual

 

–  contains  detailed  description  on  how  to  use  the  IBDRW100-P  Series 

DIN Rail Box PC, its components and features. 

 

Note: 

Some pictures in this guide are samples and can differ from actual product. 

Document Revision History

 

Version 

Date 

Note 

1.0 

10-Feb-2020 

New document release. 

 

 

Summary of Contents for IBDRW100-EX-P

Page 1: ...tions carefully before using this product and save this manual for future use DIN Rail Box PC IBDRW100 P IBDRW100 EX P Intel Pentium Processor N4200 1 1 GHz up to 2 56 GHz User Manual Version 1 0 Document Part No 917111101106 ...

Page 2: ...r 12 2 1 5 Serial Port RS 232 422 485 Connector 12 2 1 6 Isolated RS422 485 Connector 13 2 1 7 Audio Jack 13 2 1 8 DIDO Connector 13 2 1 9 DC Power 3pin Terminal Block 14 2 2 Configuring COM2 Settings by Jumpers 14 Chapter 3 Initial Setup 15 3 1 DIN Rail Mounting Setup 15 3 2 Cable ARM Bracket Installation Optional forIBDRW100 EX P 16 3 3 Enclosure for IBDRW100 EX P 17 Chapter 4 Insyde BIOS Setup ...

Page 3: ...Chapter 5 Driver Installation 42 5 1 Chipset Driver Installation 42 5 2 Graphics Driver Installation 44 5 3 TXE Driver Installation 48 5 4 Audio Driver Installation 50 5 5 LAN Driver Installation 52 Appendix 55 Appendix A Hardware Specifications 55 Appendix B Approvals and Certifications 57 ...

Page 4: ...e invoice date If the customer discovers a defect we will at his her option repair or replace the defective product at no charge to the customer provide it is returned during the warranty period of one year with transportation charges prepaid The returned product must be properly packaged in its original packaging to obtain warranty service If the serial number and the product shipping data differ...

Page 5: ...nel should open the PC chassis Avertissement Toujours débrancher le cordon d alimentation du chassis lorsque vous travaillez sur celui ci Ne pas brancher de connections lorsque l alimentation est présente Des composantes électroniques sensibles peuvent être endommagées par des sauts d alimentation Seulement du personnel expérimenté devrait ouvrir ces chassis Caution Always ground yourself to remov...

Page 6: ...afety reasons only qualified service personnel should open the equipment All cautions and warnings on the equipment should be noted Caution Always ground yourself to remove any static charge before touching the board Modern electronic devices are very sensitive to static electric charges As a safety precaution use a grounding wrist strap at all times Place all electronic components in a static dis...

Page 7: ...DRW100 EX P The documentation set for the IBDRW100 P Series DIN Rail Box PC provides information for specific user needs and includes User Manual contains detailed description on how to use the IBDRW100 P Series DIN Rail Box PC its components and features Note Some pictures in this guide are samples and can differ from actual product Document Revision History Version Date Note 1 0 10 Feb 2020 New ...

Page 8: ...d DIN Rail Box pc for hazardous location deployment and for ATEX certified Box PC requires special enclosure box The IBDRW100 P Series are certified to support the ecosystem of AWS IoT Greengrass giving customers more options for software integration for IoT applications 1 2 Product Features Highlights Class 1 Division 2 ATEX Zone 2 device certified for hazardous area IBDRW100 EX P Designed for in...

Page 9: ...6W12V6 Varies by the country Part No 94J602G030K0 Part No 94EL02X020E0 User Manual DIN Rail Mounting Clip Terminal Block 10 pin female connector for DIDO x 2 Terminal Block 3 pin Connector for Power Part No 917111101106 Part No 90ME01000000 Part No 604530005D01 Part No 604520105001 Cable Holder Kit only for IBDRW100 P EX Part No 821118561K00 x 2 Part No 821118561K01 Part No 821118561K02 ...

Page 10: ...0 EX P User Manual 1 3 Chassis Dimensions Unit mm 1 4 Description of Parts Front 1 VGA 2 RS232 422 485 3 LAN 4 LAN 5 USB 6 Audio Jack Rear 7 Isolated RS422 default RS485 as optional 8 DIDO 9 Power terminal Block 9 36V DC IN ...

Page 11: ... connect external devices such as mouse or keyboard to the box computer Pin assignment and signal names of USB connector 2 1 3 RJ 45 for Giga LAN Connector The IBDRW100 P IBDRW100 EX P have two Ethernet connectors located on the front Ethernet ports provide a standard RJ45 10 100 1000 Mbps jack connector with LED indicators on the front side to show its Active Link status and Speed status Pin assi...

Page 12: ...e IBDRW100 P IBDRW100 EX P have one COM1 9 pin D sub connectors that offer RS 232 422 485 serial communication interface ports Default setting is RS 232 but this can be modified by BIOS Pin assignment and signal names of RS 232 422 485 connector Pin Signal Name Pin Signal Name 1 RED 2 GREEN 3 BLUE 4 NC 5 GND 6 GND 7 GND 8 GND 9 5V 10 GND 11 NC 12 SDA 13 HSYNC 14 VSYNC 15 SCL Pin RS 232 Default RS4...

Page 13: ...he IBDRW100 P IBDRW100 EX P have has three stereo audio ports with audio jack connectors Mic in Line out Line in Pin assignment and signal names of audio jack 2 1 8 DIDO Connector Pin assignment and signal names of DIDO connector Pin RS422 RS485 1 Tx DATA 2 Tx DATA 3 RX NC 4 RX NC 5 GND GND 6 NC NC 7 NC NC 8 NC NC 9 NC NC Color Signal Name BLUE Line in GREEN Line out PINK Mic in Pin Signal Name Pi...

Page 14: ...ut endommagé l appareil et ses pièces Note A pair of needle nose pliers may be helpful when working with jumpers If you have any doubts about the best hardware configuration for your application contact your local distributor or sales representative before you make any changes Generally you simply need a standard cable to make most connections The jumper setting diagram is shown below When the jum...

Page 15: ...RW hook kit on a DIN rail 1 Screw the provided DIN rail Kit on the rear side of the box as the diagram shown below 2 Please make sure the stiff metal handle part is located on the top 3 Press the stiff metal handle downward and insert the hook into the DIN rail 4 Release the handle so it can snap into place as shown below ...

Page 16: ...acket can be use to secure some LAN USB and Audio connectors Follow these steps to complete the installation 5 Find the cable arm bracket in the package including the plate bracket holder and screws 6 Install the plate on the top of the box and screw it tightly 7 Plug all the necessary cables into the connectors 8 Place the cable arm bracket according to the picture and then attach the bracket hol...

Page 17: ... for deployment in hazardous location including Chemical and Petrochemical Industries Offshore energy Pharmaceutical industry Grain handling and processing Caution Attention Make sure the specific mounting position for the Enclosure Please ensure that the surface of the wall skid is flat to avoid distortion of the enclosure Not to exceed maximal temperature All the cables must be made with a parti...

Page 18: ...h a cloth 2 Please check if there is any damage on the surface of the box 3 Please check the tightness of the connections wires Follow these steps to install the IBDRW100 EX P inside of the enclosure box 1 Attached DIN Rail adapter to the BDRW100 EX P Box PC using the screws provided 2 Mount the DIN rail inside of the enclosure Box 3 Press the stiff metal handle from DIN Rail adapter downward and ...

Page 19: ... Error message on screen indicate to check BIOS Setup 2 Restoring the Factory default setting 3 Modifying the specific hardware specification 4 Want to optimize the specification 4 1 2 BIOS Setup Keys The following keys are enabled during POST Key Function Del Enters the BIOS setup menu F7 Display the boot menu Lists all bootable devices that are connected to the system With cursor and cursor and ...

Page 20: ...anguage Select the current default language by the Insyde20 Adjustment of the language Default English Set the default language System Time The time is maintained by the battery when the device is turned off Adjustment of the time Set the time in the format hh mm ss System Date This is current date setting The time is maintained by the battery when the device is turned off Changes to the date Set ...

Page 21: ...rs Enter Opens submenu South Cluster Configuration Setting South Cluster Configuration parameters Enter Opens submenu Security Configuration Setting Security Configuration parameters Enter Opens submenu Thermal Configuration Setting Thermal Configuration parameters Enter Opens submenu S10 F81866A Setting S10 F81866A parameters Enter Opens submenu H2oUve Configuration Setting H2oUve Configuration p...

Page 22: ...22 IBDRW100 P IBDRW100 EX P User Manual 4 2 3 1 USB Configuration BIOS Setting Description Setting Option Effect OS Selection OS selection Windows Linux Select OS Default Based on your order ...

Page 23: ...T Pre Allocated Select DVMT5 0 Pre Allocated Fixed Graphics Memory size used by the Internal Graphic Device 32M 64M 96M 128M 160M 192M 224M 256M 288M 320M 352M 384M 416M 448M 480M 512M Select DVMT Pre Allocated DVMT Total Gfx Mem Select the size of DVMT Dynamic Video Memory 5 0 that the Internal Graphics Device will use 128M 256M MAX Select DVMT Total Gfx Mem Cd Clock Frequency Select Cd Clock Fre...

Page 24: ...ting Option Effect PCI Express Configuration PCI Express Configuration Settings Enter Opens sub menu SATA Drives SATA Drives Settings Enter Opens sub menu USB Configuration USB Configuration Settings Enter Opens sub menu Miscellaneous Configuration Miscellaneous Configuration Settings Enter Opens sub menu ...

Page 25: ...les Peer Memory Write Enable Compliance Mode Enables or disables Compliance Mode for this PCIe port Enabled Disabled Enables or disables Compliance Mode PCI Express Root Port 2 Lane 5 Control the PCI Express Root Port Auto To disable unused root port automatically for the most optimum power savings Enable Enable PCI Root Port Disable Disable PCI Root Port PCI Express Root Port 4 Lane 1 Control the...

Page 26: ...26 IBDRW100 P IBDRW100 EX P User Manual ...

Page 27: ...he use of advanced features on SATA drives IDE In IDE mode the hard drive is set to run as an IDE or Parallel ATA PATA hard drive RAID RAID mode allows several hard disk drives to function as one storage area the array to provide either data redundancy backup security or faster performance striped reading writing data from or to the disk drives SATA Interface Speed Select SATA Interface Speed Gen1...

Page 28: ... Port Control Control each of the USB port 0 7 enable disable Enabled Disabled Enables or disables each of the USB port XDCI Support Disable the XDCI support or enable PCI Mode Enabled Disabled Enables or disables XDCI Support XMCI Disable Compliance Mode XMCI Disable Compliance Mode settings TRUE FALSE Enables or disables ...

Page 29: ...ption Effect High Precision Timer High Precision Timer settings Enabled Disabled Enable or disable the High Precision Timer 8254 Clock Gating 8254 Clock Gating settings Enabled Disabled Enable or disable8254 Clock Gating State After G3 State After G3 settings S0 State S5 State System power state setting ...

Page 30: ...30 IBDRW100 P IBDRW100 EX P User Manual 4 2 3 4 Security Configuration BIOS Setting Description Setting Option Effect Target TPM device Select Target TPM device dTPM Select Target TPM device ...

Page 31: ... throttling the processor Passive TC1 Value This value sets the TC1 value for the ACPI Passive Cooling Formula 1 16 Sets the TC1 value for the ACPI Passive Cooling Formula Passive TC2 Value This value sets the TC2 value for the ACPI Passive Cooling Formula 1 16 default 5 Sets the TC2 value for the ACPI Passive Cooling Formula Passive TSP Value It represents in tenths of a second how often the OS w...

Page 32: ...O Serial Port B AUTO Serial Port C AUTO Serial Port D DISABLE Disabled No configuration Enabled User configuration Auto EFI OS chooses configuration WDT Time out controller settings Enabled Disabled Enables or disables Time out controller Hardware Monitor Hardware Monitor settings Enter Opens sub menu GPIO Group 0 8 Configuration GPIO Group 0 8 Configuration settings Enter Opens sub menu Serial Po...

Page 33: ...33 Chapter 4 Insyde BIOS Setup WDT ...

Page 34: ...34 IBDRW100 P IBDRW100 EX P User Manual Hardware Monitor 4 2 4 H2oUve Configuration ...

Page 35: ... Security BIOS Setting Description Setting Option Effect TrEE Protocol Version TrEE Protocol Version 1 0 or 1 1 TrEE Protocol Version TPM Availability Configure TPM Availability settings Available Set TPM Availability TPM Operation Configure TPM Operation settings No Operation Set TPM Operation Clear TPM Clear TPM Clear TPM Set Supervisor Password Set Supervisor Password Enter Opens sub menu ...

Page 36: ...ting Option Effect CPU Configuration Setting CPU Configuration parameters Enter Opens sub menu Wake on PME Power Management Even from S5 state Force Enable Power Management Even after S5 state Wake on RTC from S5 Wake on RTC from S5 state Enabled Disabled Wake on RTC from S5 state ...

Page 37: ...37 Chapter 4 Insyde BIOS Setup 4 2 7 Boot ...

Page 38: ...le or enable booting in text Mode Network Stack Network Stack configuration Enabled Disabled Network Stack Support Windows 8 Bitlocker Unlock UEFI IPv4 IPv6 PXE Legacy PXE OPROM Power Up In Standby Support Power Up In Standby Support Enabled Disabled Enables or disables Power Up In Standby Support Add Boot Options Boot Options settings First Boot Options settings USB Boot USB Boot settings Enabled...

Page 39: ...39 Chapter 4 Insyde BIOS Setup 4 2 8 Exit ...

Page 40: ...changes without exit system setup Enter Opens sub menu Exit Discarding Changes Exit system setup and discard your changes Enter Opens sub menu Load Optimal Defaults Load optimal system defaults Enter Opens sub menu Load Custom Defaults Load custom system defaults Enter Opens sub menu Save Custom Defaults Save custom defaults Enter Opens sub menu Discard Changes Discard changes Enter Opens sub menu...

Page 41: ...very procedure Plug in the AC adapter to Box PC Make sure the Box PC stays plugged in to power source during the recovery process Turn on the IBDRW100 P IBDRW100 EX P DIN Rail Box PC and when the boot screen shows up press the F6 to initiate the Recovery Wizard The following screen shows the Recovery Wizard Click on Recovery button to continue A warning message about data loss will show up Make su...

Page 42: ... Windows 10 IoT Enterprise operating system 5 1 Chipset Driver Installation Follow the instructions below to complete the installation You will quickly complete the installation Step 1 Insert the CD that comes with the IBDRW100 P IBDRW100 EX P DIN Rail Box PC Open the file Chipset Driver Click SetupChiset Step 2 Click Next to install driver ...

Page 43: ...apter 5 Driver Installation Step 4 Check the License Agreement and click Accept to continue Step 5 Check Readme File Information and click Install to continue Step 7 Wait for the system to install the driver ...

Page 44: ...effect Click Restart Now 5 2 Graphics Driver Installation IBDRW100 P IBDRW100 EX P DIN Rail Box PC is equipped with Intel SoC Integrated Device Follow the instructions below to complete the installation You will quickly complete the installation Step 1 Insert the CD that comes with the IBDRW100 P IBDRW100 EX P DIN Rail Box PC ...

Page 45: ...is extracting files Please wait while the InstallShield Wizard extracts the files needed to install Intel Graphics Driver Software to your computer This may take few moments Step 4 Select automatically run WinSAT and enable the Windows Aero desktop theme if supported and click Next ...

Page 46: ...W100 EX P User Manual Step 5 Check the License Agreement and click Yes to continue Step 6 Check Readme File Information and click Install to continue Step 6 Please wait while the following setup operations are performed ...

Page 47: ...47 Chapter 5 Driver Installation Step 7 Click Next to continue Step 7 Select Yes I want to restart this computer now and click Finish ...

Page 48: ...r Manual 5 3 TXE Driver Installation Follow the instructions below to complete the TXE Driver installation Step 1 Insert the CD that comes with the IBDRW100 P IBDRW100 EX P DIN Rail Box PC Click SetupTXE Step 2 Click Next to continue ...

Page 49: ...iver Installation Step 3 Check the License Agreement select I accept the terms in the License Agreement and click Next to continue Step 4 Click Next to continue Step 5 Please wait while the product is being installed ...

Page 50: ...lick Next to exit installation window 5 4 Audio Driver Installation Follow the instructions below to complete the TXE Driver installation Step 1 Insert the CD that comes with the IBDRW100 P IBDRW100 EX P DIN Rail Box PC Open Audio folder Click Setup ...

Page 51: ...51 Chapter 5 Driver Installation Step 2 Click Next to continue Step 3 Wait for the system to install files Step 4 Select Yes I want to restart this computer now and click Finish ...

Page 52: ...LAN Driver Installation Follow the instructions below to complete the LAN Driver installation Step 1 Insert the CD that comes with the IBDRW100 P IBDRW100 EX P DIN Rail Box PC Open LAN folder Open archived file Step 2 Installation is in progress ...

Page 53: ... Chapter 5 Driver Installation Step 3 Click Next to continue Step 4 Check the License Agreement select I accept the terms in the License Agreement and click Next to continue Step 5 Click Next to continue ...

Page 54: ...54 IBDRW100 P IBDRW100 EX P User Manual Step 6 Wait for the system to install files Step 7 Click Finish to exit installation window ...

Page 55: ...l 4G U2MPE 120 Optional 4G U2MPE 120 Interface External I O 3 x USB 3 0 1 x USB 2 0 4 x RJ 45 for Giga LAN w LED 1 x VGA 1 x RS232 Default RS422 485 switch by BIOS 1 x Isolated RS422 Default RS485 Switch by jumper 1 x Audio Jack Mic in Line out Line in 1 x clear CMOS reset button 1 x DIDO 9in 9out 1 x DC Power 3pin Terminal Block 3 x USB 3 0 1 x USB 2 0 4 x RJ 45 for Giga LAN w LED 1 x VGA 1 x RS2...

Page 56: ...Operating Humidity 5 to 95 RH non condensing 5 to 95 RH non condensing Shock MIL STD 810F G Method 516 6 MIL STD 810F G Method 516 6 Vibration MIL STD 810F G Method 514 6 MIL STD 810F G Method 514 6 Approvals and Certifications Ordinary Location Safety UL60950 1 CSA C22 2 No 60950 1 07 EN60950 1 IEC60950 1 UL60950 1 CSA C22 2 No 60950 1 07 EN60950 1 IEC60950 1 Hazardous Location Safety N A ATEX II...

Page 57: ... EC Independent 3rd party assessment European Union This equipment is in conformity with the requirement of the following EU legislations and harmonized standards Product also complies with the Council directions Electromagnetic Compatibility Directive 2014 30 EU EN55024 2010 A1 2015 o IEC61000 4 2 2009 o IEC61000 4 3 2006 A1 2007 A2 2010 o IEC61000 4 4 2012 o IEC61000 4 5 2014 o IEC61000 4 6 2014...

Page 58: ...________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ ___________________...

Page 59: ...________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ ___________________...

Page 60: ...Winmate Inc 9F No 111 6 Shing De Rd San Chung District New Taipei City 24158 Taiwan R O C www winmate com Copyright Winmate Inc All rights reserved ...