Temperature and Humidity Control WM-CONTROL-SS 

 
 
15S-601  is  microprocessor-based  controller  to  be  connected  to  the  15S-602 
keypad by means of a two-wire cable at a distance of up to 100 ft. It is provided 
with  four  relay  outputs  to  control  liquid  line  solenoid  valve,  evaporator  fan 
(adjusting  humidity),  and  alarm  auto-dialer  and  cellar  heater.  It  is  also  provided 
with  up  to  4  NTC  or  PTC  probe  inputs  for  cellar  temperature  and  evaporator 
temperature control, bottle temperature and condenser temperature monitor. The 
controller  is  fully  configurable  through  special  parameters  that  can  be  easily 
programmed  through  the  keypad.  The  controller  can  be  connected  to  internet 
based 15S-WEB module through external module 15S-CX. The keypad is thin and 
has a stainless steel face which can be perfectly integrated into a wall. 
 

1. Keypad and Controller 

 
 

          

 

 
 

1) How to use keypad 

 

SET

To display set-point; in programming mode it selects a parameter or confirms 

an operation. 

To start a manual defrost. 

To see the maximum stored temperature; in programming mode it browses 

parameters or increases displayed values. 

To see the minimum stored temperature; in programming mode it browses 

parameters or decreases displayed value. 

To turn on or off the power to the unit.

 

 +

  : 

To lock or unlock the keypad. 

SET 

+

 : 

To enter in the programming mode.

 

SET 

+

 : 

To return to the

 

temperature display.

  

 
 

Summary of Contents for 15S-601

Page 1: ...trol Installation Use Care Manual WM CONTROL SS www vinotemp com Vinotemp International Corp 17631 S Susana Road Rancho Dominguez CA 90221 Tel 800 777 VINO Fax 310 886 3310 Email info vinotemp com Read and save these instructions ...

Page 2: ...rs that can be easily programmed through the keypad The controller can be connected to internet based 15S WEB module through external module 15S CX The keypad is thin and has a stainless steel face which can be perfectly integrated into a wall 1 Keypad and Controller 1 How to use keypad SET To display set point in programming mode it selects a parameter or confirms an operation To start a manual d...

Page 3: ...ing to Con and CoF HA High temperature alarm Probe temperature ALU higher than the setting temperature Outputs unchanged LA Low temperature alarm Probe temperature ALL lower than the setting temperature Outputs unchanged CA External alarm All outputs off Probe alarms P1 start a few seconds after the fault in the related probe they automatically stop a few seconds after the probe restarts normal op...

Page 4: ...for more than 3 seconds The compressor and liquid line solenoid valve indicator will be displayed 7 How to program parameters 1 Press and hold SET and until the C or F LED starts flashing then release the keys 2 Press and hold again the SET and keys until the Pr2 label is displayed then release the keys The first parameter Hy will be displayed 3 Press or to scroll to the required parameter within ...

Page 5: ...meters are used 8 How to calibrate the air probe If the actual cellar temperature differs from the setting temperature set parameter ot actual cellar temperature minus set point 9 How to adjust defrost cycle In case there is excessive frost the parameters FnC C y idF 4 and MdF 20 can be used to avoid frost 10 How to adjust the humidity The parameter Fon is used to adjust the humidity in the wine c...

Page 6: ... contactor 13 Controller Electrical Wiring Diagrams NOTES To use call feature connect the terminals 20 and 21 to the auto dialer power supplier 120V input To use cellar heater feature connect the terminals 22 and 23 to the cellar heater 120V input To use bottle probe feature connect the terminals 2 and 3 to the bottle probe input 1 FAN COIL 120V Electrical Wiring WM SFCD WM SFCI WM SFCL WM SFCO WM...

Page 7: ... 6 2 AIR HANDLER 120V Electrical Wiring WM SFCA WM SFCH WM SFCR WM SFCV 3 CONDENSING UNIT 120V Electrical Wiring WM 150 450SCUR ...

Page 8: ... 7 4 CONDENSING UNIT 120V Electrical Wiring WM 650SCUR 5 CONDENSING UNIT 120V Electrical Wiring WM 850SCUR ...

Page 9: ... 8 6 CONDENSING UNIT 230V Electrical Wiring WM 1203SCUR 7 CONDENSING UNIT 120V Electrical Wiring WM 250 650SCUR WC ...

Page 10: ... 9 8 CONDENSING UNIT 120V Electrical Wiring WM 850SCUR WC 9 CONDENSING UNIT 230V Electrical Wiring WM 1203SCUR WC ...

Page 11: ...10 Customer Support If you need further assistance please contact us at Vinotemp International 17631 South Susana Road Rancho Dominguez CA 90221 Tel 310 886 3332 Fax 310 886 3310 Email info vinotemp com ...

Page 12: ...INOTEMP with respect to its products and is in lieu of all other warranties express or implied including any of fitness for a particular purpose In no event shall VINOTEMP be responsible for any consequential damages what is so ever Any modification or unauthorized repair of VINOTEMP products shall void this warranty Service under Warranty This service is provided to customers within the continent...

Page 13: ...E UNIT LOSS OF TIME OR COMMERCIAL LOSS ANY OUTER DAMAGES WHETHER INCIDENTAL CONSEQUENTIAL OR OTHERWISE THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR INPLIED INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE While great effort has been made to provide accurate guidelines VINOTEMP cannot warrant its units to proper...