8
6. Opening and locking surveillance
In combination with the Winkhaus activPilot
fitting system it is also possible to use the
wireless contact for combined opening and
locking surveillance. To learn more, please
turn to a window specialist.
①
E1.VS.KG
②
MK.VS.150.KG
③
Moving magnetic contactors
The E1.VS.KG is preferred for use. It is
mounted at the bottom of the drive side. In
case of double sash windows, the
interlocking rods MK.VS.150.KG or
MK.VS.250.KG are used. As the radio
contact is not subject to VdS guidelines, the
sensor may also be mounted on the hinge
side.
Regarding installation and positioning of
the radio contact for opening and locking
surveillance it must be made sure that the
window is already locked when the sensor
gives the locking signal. This means the
locking bolts must have entered 50 % into
the locking keeps.
The installation position of the radio contact
on the frame depends on the travel path of
the fitting system. Positioning of the
wireless contact in relation to the movable
contactor is described below, using the
example of the corner drive E1.VS.KG.
①
Closed
②
Turn
③
Tilt
7. Maintenance and cleaning
Battery replacement
At the end of the battery’s service life, the
radio performance of the sensor is
impaired. In case you notice such an
impairment of performance, you need to
replace the battery. To do so, open the