1.6
Reader
Reader
The reader can be installed as an addition to electronic cylinders. A
distinction is made between a reader with an internal and an external
control unit (
).
The reader can be used to control motorised locks, parking barriers or
electric garage doors, for example.
Reader types
Reader with internal control unit:
•
The reader with internal control unit has an integrated switching
mechanism which controls the access function directly. The wiring
takes place directly with the periphery devices to be controlled.
Readers with external control unit:
•
With this reader type, we differentiate between reader and control
unit. The communication between the reader and control unit takes
place encrypted via a signal line. The switching mechanism is
integrated in the control unit in the protected interior.
The following components are required for installing the two reader
types and are included with the reader:
•
Two dowels (diameter: 4 mm)
•
Two screws
•
Connection cable with a length of 4.5 m
•
Drilling template
•
Installation of reader types
There are two different installation situations for installing the two
reader types:
see "Install reader with internal control unit", page 48
see "Install reader with external control unit", page 51
Controlling the reader
The access authorisation is issued by the reader or the external control
unit when an authorised key is held in the centre in front of the reader.
The release by the reader is indicated visually by the illuminated LED and
acoustically with a beeping sound.
All authorisation and adjustment options
22