background image

Disassemble and remove the lock 

body from the container or door. 

Turn the lock over so the cables 

and plastic tube retainer are 

visable. 

 

 

 

Insert the T-6 Torx Bit, supplied 

with the X-09/X-10 Service Tool, 

into the tool and remove the 

screw holding the tube retainer 

on to the lock case. 

 

 

 

Carefully remove the tube  

retainer.  

Note: The Ground Contact will 

probably be stuck to the Tube  Retainer 

with grease, please be aware of this and 

make sure it is in place when re-

installing the tube retainer. The cable 

plug should now be visable.

Note: 

The X-10 plastic tube retainer is 

shorter and is located in a different spot. 

If using an X-10 ribbon cable assembly 

kit, make sure to use the plastic tube 
retainer that’s on the X-09. 

 

 

Remove the cable plug and  

damaged cables and discard.

 

 

 

 

Remove the protective cover off 

of the contacts of the new cables 

and insert them into the lock case 

as shown. 

 

Replacing the Ribbon Cable on the X-09/X-10

TM

X-09

X-10

X-10

X-09

(1)

(2)

(3)

(4)