Feed the cables through the slot 

in the tube retainer making sure 

the cables are nor crimped or 

damaged. Make sure the tube 

retainer is oriented correctly so 

that it will seat flush against the 

lock case.

 

Seat the tube retainer properly, 

making sure it’s tab is inserted 

into the lock case. Don’t forget to 

install the ground contact as well. 

Keep the cables pulled  

tight as you are seating the  

tube retainer so that none of the 

excess cable is caught under the 

tube retainer as it is being seated 

into place. 

 

 

The cables should look like the 

photo when installed properly. 

Hold the tube retainer in place, 

insert and tighten the screw  

holding the tube retainer.

 

 

 

Replacement of Ribbon Cable 

Complete.

Re-install the X-09/X-10 lock and check for proper operation. 

Please note that Kaba Mas provides a NEW tube retainer, ground contact and screw with all cable 

sets. Inspect and replace these parts if worn, damaged or lost. 

Call Customer Service at 800-654-0637 to place your order.