5
Select and install reader
5.1
Select reader
Different both reader types can be integrated into the locking system. The
place of use determines whether a reader with external or internal control
unit is installed.
•
A reader with internal control unit is suitable for use indoors.
•
It is advisable to install a reader with external control unit in outdoor
areas, where there is an increased risk of break-in and vandalism. The
control unit is mounted in the secure internal area.
5.2 Install reader
Note
Material damage due to incorrect installation of
the reader!
Incorrect installation of the reader can result in
damage or destruction of the reader and the
connected electronics.
•
Assembly, programming and disassembly may
only be carried out by specialist personnel
according to IEC 62368-1.
•
It is recommended to provide a cut-off device
for the power supply.
•
If inductive loads are connected, the supplied
suppressor diode (freewheeling diode) must be
fitted parallel to the load to protect the relay
contacts.
•
Carry out the installation in accordance with
these instructions.
•
Only mount the switching mechanism in
deenergised state.
5.3 Install reader with internal control unit
Staff:
•
Qualified electrician for energy and building technology
Protection equipment:
•
Safety shoes
•
Hearing protection
Special tools:
•
Impact drill incl. drill set
•
Drilling template
•
Voltmeter
Materials:
•
Dowel
•
Taut wire
•
Screws
Requirements
•
Empty conduit for cable routing has been laid.
•
Reader and reader cable are ready.