CLEANING FRONT GRILLS AND AIR FILTER 

1. Remove front grill by pulling out bottom towards

    you (Fig.1).  Then hold the top of the grill and 

    lift up gently to remove grill completely (Fig.2).

2. Pull the bottom of the filter out and lift the filter

    out (Fig.3).

Note : The filter is extremely flexible.

The removal of the filter will not damage the filter

3. Wash with mild detergent and rinse thoroughly.

    Air dry away from direct sunlight.

4. Install filter and grill back into unit following 

    reverse directions listed above.

5. FRONT GRILL can be cleaned using a vacuum

    with a soft brush attachment to remove dust 

    (Fig.4)

CARE AND MAINTENANCE

    WARNING

 Disconnect power supply cord from 

  receptacle before performing any  

  maintenance.

CLEANING THE EXTERIOR

Clean the exterior using a soft brush or dry 

towel. But do not spray water directly on the 

exterior.

CLEANING THE BUCKET 

Pull the bucket out. Lift off bucket cover. 

(Fig.1) Clean the inside of bucket every week 

using mild detergent in order to block buildup 

of mold and bacteria. (Fig.2)
After cleaning, replace the bucket cover 

and slide the bucket into the unit. (Fig.3) 

Check the 

floa

t switch to make sure it is not 

obstructed. Proper position of the bucket 

and the 

floa

t switch is required for the 

dehumidifie

r to turn on.

 Fig.1   

Fig.2

 Fig.3

Float Switch 

Fig.1 

 

Fig.2

 Fig.3   

Fig.4

WATER DISPOSING OPTIONS

OPTION 1, EMPTYING MANUALLY 

1. Pull out the bucket, grasping upper and lower 

    handles.

2. Carry the bucket by grasping the inside handle 

    of the bucket.

3. After emptying the bucket, replace the bucket in 

    the dehumidifier.

NOTE: Dehumidifier will not work when the BUCKET 

FULL light is on or without the bucket properly placed 

in the unit. 

OPTION 3, PUMP DRAIN

1. Remove the PUMP DRAIN CAP by turning 

    clockwise (Reverse thread). (Fig.1) 

2. 

Remove the drain-hole GREY RUBBER PLUG by

    pulling out while pressing in on the coupler. (Fig.2)

    

Keep the DRAIN CAP and PLUG for future use.

3. Feed the 1/4-inch hose provided through the hole 

    in the DRAIN CAP. (Fig.3)

4. Insert the end of hose into the drain hole (Fig.4), 

    then screw DRAIN CAP back onto the unit. Place 

    the other end of the hose in the location you want 

    

the water to go: to a floor drain, a water container, 

    or through a basement window to the outdoors. 

    (Pump can lift water up to 15 feet above the unit.) 

    Check hose for kinks or other obstruction. Make 

    sure end of hose will not be submerged in water 

    as this may cause a backflow into the unit and 

    cause a leak.

OPTION 2, GRAVITY DRAIN HOSE

(Garden Hose Not Provided)

1. Take off GRAVITY DRAIN CAP by turning the 

    cap counterclockwise. (Fig.1)

2. Remove DRAIN CONNECTOR from the bucket.

    (Fig.2)

3. Next, screw the DRAIN CONNECTOR to a 

    standard garden hose by turning clockwise. 

    (Fig.3)

4. Reattach the DRAIN CONNECTOR end of 

    garden hose to the dehumidifier (Fig.4) then 

    check hose for kinks or obstructions. The position 

    of the hose at the floor drain must be lower than 

    DRAIN CONNECTOR.

5. Keep the DRAIN CAP for future use when 

    emptying bucket manually. 

 

 

 

Fig.1

Fig.2

Fig.3

Fig.4

Fig.1

Fig.2

Fig.3

Fig.4

5. In the unlikely event the hose comes loose during 

    pump operation due to vibration, re-attach hose 

    to continue automatic pump removal of water. 

CAUTION: Do not remove the bucket while 

the pump is operating. This will cause the dehumidifier 

to stop operating and result in an “E3” error message. 

ALSO: The pump drain hose should not be both 

under water AND at a height that is above the 

dehumidifier. This can cause a “back flow” to the 

dehumidifier and cause the dehumidifier to stop 

working resulting in an “E3” error message. Following 

an “E3”error, the unit must be unplugged and reset 

to operate. (See Error Code section of this manual.)

Pressing

Filter should be cleaned every 2 weeks during