background image

10 

11

Specification

Remark

24-Hour Period

5% Increments

320g/280g

High/Low
400x668x338mm

Classification

36°F-99°F

12V DC

0.25 in X 18 ft

(6.35 X 5,486 mm)

WDH 871

AC 115V/60(Hz)

70 Pints

Electronic

35-70%

3,6,12 Hr

2 Stage

47.8 lbs

(21.7Kg)

15.75X26.3X13.31 in

R-410A / 11.29 OZ

36°F-99°F

0.25 in X 18 ft

(6.35 X 5,486 mm)

12V DC

WDH 851

AC 115V/60(Hz)

50 Pints

Electronic

35-70%

3,6,12 Hr

46.7 lbs

(21.2Kg)

15.75X26.3X13.31 in

2 Stage

R-410A / 9.88 OZ

Model
Power Supply
Moisture Capacity
Control Type
Refrigerant
Humidity Setting
Cycle Run Time
Fan Motor Speed
Dimensions

Net Weight

Operating Temp.
Drain Pump

Pump Drain Hose

Recommended 

Room Size

Winix dehumidifiers are suitable for use in large

basements to small rooms.

Error 

Code

Error Type

Possible Causes Corrective Actions

E3

Pump Drain

1. Improper 

    bucket 

    installation.

2. Blockage to 

    drain hose 

    system.

3. Back 

flow

 of 

    water through 

    pump drain 

    hose.

4. Improper pump 

    drain hose 

    installation.

5. Faulty drain 

    pump.

1. Unplug the dehumidifie

r.

2. Remove the bucket.

3. Check to make sure that there is nothing

    blocking the connection at the base of the

    pump or the bucket.

4. Reinstall the bucket, taking care that it is

    installed properly.

5. Check to make sure that the pump drain

    hose is not crimped or blocked.

6. Check to make sure that the pump drain

    hose is not both under water and sitting at

    a height above the dehumidifier – this can

    cause a “back flow” of water from the hose

    to the dehumidifie

r. 

7. Remove and reinstall the pump drain hose,

    taking care that the pump drain hose is

    installed properly.

8. Plug the dehumidifier in and restart

PRODUCT SPECIFICATIONS

ERROR CODES

TROUBLESHOOTING

Before calling for service, try the suggestions below to see whether you can solve your 

problem without outside help.

PROBLEMS

CHECK POINT                                              SOLUTIONS

Dehumidifie

r does not 

work when pressing 

the POWER ON 

button.

Is the power cord plugged into 

a grounded 3-prong outlet? 

Is BUCKET FULL light on?
Does BUCKET FULL light 

appear after emptying the 

water bucket?

Plug the power cord securely into a 

grounded 3-prong outlet. 
Empty the water bucket and 

re-install. 
Check the 

floa

t switch to make sure 

it is free and not obstructed.

Dehumidifier is running, 

but not drawing any 

water

 

 

Is the compressor running as 

well as the fan?
Is there frost on the coils?
Is the season late fall, winter,

or early spring?

The unit may be in the defrost 

mode. The fan is running but not the 

compressor. The unit will return to 

dehumidificatio

n

Generally when temperatures drop 

outside during colder seasons, 

humidity levels drop causing the 

amount of moisture in the air to be 

minimal.  This will result in the unit 

not drawing as much water as it does 

during warmer seasons.

 automatically.

Loud noise and/

or vibration during 

operation.

Is the unit on a level surface? Move the unit to a level surface.

Sounds.

Sounds like 

flowin

g water 

during and after operation.
It makes a pinging sound.

This is the normal sound of the 

refrigerant 

flowin

g through the coils.

Normal sound of expansion and 

contraction caused by temperature 

changes.

Low airflow out of

machine.   

Are the 

filter

s and grills dirty? Clean the FRONT GRILL and AIR

 

 

 

 

 

 

FILTER.

Water does not drain 

through garden hose.

Check the DRAIN CON-

NECTOR making sure it is 

installed securely. 
Check the garden hose for 

tangles or folds.

Re-install it according to this manual. 

Flatten the hose or remove block-

age.

Water does not drain 

through pump drain 

hose.

Check the connecting hose

for tangles or folds.

Does pump display light 

appear?

Re-install drain hose according to 

this manual.
Flatten the hose or remove blockage.
Turn on the pump.