background image

WATER DISPOSING OPTIONS  

6

7

CONTROL PANEL 

POWER ON/OFF (1)

Pressing button once turns the unit "ON" 

and pressing it again turns the unit "OFF".

COMFORT (2)

When the unit is turned on or by pressing button

once, operation begins in comfort mode. 

"At" will appear in the 

display(7) 

and the

comfort indicator(8)

 will light up. In this setting,

humidity level is adjusted for optimum comfort

with no manual adjustment needed. When

pressing the button again, comfort mode is

turned off and the unit will adjust humidity

level based on the humidity level entered.  

HUMIDITY (3)

To set desired humidity level when not in comfort

mode, push this button until desired humidity level

is reached. The humidity levels will adjust in 

increments of 5% beginning at a low of 35%

and reaching a maximum of 70%. Humidity will

show in the display when adjusting humidity.

When humidity level has reached 70%, pushing

once more will set unit into continuous mode. 

Continuous mode will run the unit continuously

until it is turned off or until another setting is inputted.

When continuous mode is programmed, “On” 

will be displayed.    

TIMER (4)

By pressing this button, the unit will run until the

desired time expires. Timer range is between 1

and 12 hours with increments of 1 hour. The 

desired time remaining until shut off is shown in 

the 

display(7)

. Please note display shows setting 

time temporarily before returning to desired 

humidity level display.

FAN SPEED (5)

By pressing this button, fan speed will change.

The 

indicator(9)

 of selected fan speed will light

(High or Low). In Comfort Mode, fan speed will 

not be set as the setting will adjust the fan speed 

automatically. 

PUMP ON/OFF (6)

Pump "ON" is an optional setting when using

a drain hose to remove the collected water 

automatically. When the pump function is on,

the 

indicator(10)

 will light on. The pump button

should be off at all times except when using the

pump to remove collected water (See Page 7,

Option 3). After installing hose correctly to pump

drain, push the button for automatic water removal.

If the pump button is pressed when using other

disposal options, E3(Error message – See page

10) will be displayed. If other disposal options

are needed, push the pump button again to turn

off the pump function. 

BUCKET FULL INDICATOR (7)

When the collection bucket full, bucket full 

indicator will light on. The unit will not run with

the bucket full.  Dispose of water and replace

bucket properly. 

 

 

 

 

 

 

 

   

 

 

 

 

 

   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

       

 

 

   

     

 

 

 

 

     

 

 

 

   

 

   

 

OPTION 1, EMPTYING MANUALLY

1. Pull out the bucket, grasping upper and 

    lower handles.
2. Carry the bucket by grasping the inside   

    handle of the bucket.
3. After emptying the bucket, replace the 

    bucket in the dehumidifier.
NOTE: Dehumidifier will not work when the 

BUCKET FULL light is on or without the 

bucket properly placed in the unit.

OPTION 2, GRAVITY DRAIN HOSE

(Garden Hose Not Provided)
1. Take off GRAVITY DRAIN CAP by turning 

    the cap counterclockwise. (Fig.1)
2. Remove DRAIN CONNECTOR from the 

    bucket. (Fig.2)
3. Next, screw the DRAIN CONNECTOR 

    to a standard garden hose by turning 

    clockwise. (Fig.3)
4. Reattach the DRAIN CONNECTOR end 

    of garden hose to the dehumidifier (Fig.4)  

    then check hose for kinks or obstructions. 

    The position of the hose at the floor drain 

    must be lower than DRAIN CONNECTOR.
5. Keep the DRAIN CAP for future use when 

    emptying bucket manually. 

 

OPTION 3, PUMP DRAIN

1. Remove the PUMP DRAIN CAP by turn-   

    ing clockwise (Reverse thread). (Fig.1)
2. Remove the drain-hole PLUG by pulling out  

    while pressing in on the coupler. (Fig.2)

Keep the DRAIN CAP and PLUG for future use.

3. Feed the 1/4-inch hose provided through 

    the hole in the DRAIN CAP. (Fig.3)
4. Insert the end of hose into the drain hole 

    (Fig.4), then screw DRAIN CAP back 

    onto the unit. Place the other end of the

    hose in the location you want the water to 

    go: to a floor drain, a water container, or 

    through a basement window to the 

outdoors. (Pump can lift water up to 15 

    feet above the unit.) Check hose for kinks 

    or other obstruction.

          Fig.1                           Fig.2

          Fig.3                           Fig.4

    Fig.1   

Fig.2

B

Pressing

   Fig.3   

Fig.4

5. In the unlikely event the hose comes 

    loose during pump operation due to 

    vibration, re-attach hose to continue 

    automatic pump removal of water.

               CAUTION: Do not remove the 

    bucket while the pump is operating. This    

    will cause the dehumidifier to stop operat-

    ing and result in an “E3” error message.    

    ALSO: The pump drain hose should not  

    be both under water AND at a height 

    that is above the dehumidifier. This can 

    cause a “back flow” to the dehumidifier 

    and cause the dehumidifier to stop work-   

    ing resulting in an “E3” error message. 

    Following an “E3” error, the unit must be  

    unplugged and reset to operate. (See

    Error Code section of this manual.)

2

1

8

6

5

9

4

3

10
11

7

www.sylvane.com  1-800-934-9194

Reviews: