Floor insulation 

 
The  floor  of  the  cellar  must  be  able  to  support  the  shelves  and  the  stored  wine.  Thus,  it’s  necessary  to 
choose insulation with adequate compression strength.  
 
Improve the load capacity of the insulation (particularly under the shelve legs) by using : 
  

« Complex »

 insulation panels covered by panels of higher load capacity. 

Cover  the  insulation  panel  with  a  wooden  panel

  (at  least  15  mm  thickness),  or  any  other 

appropriate material. 

 

1.2.2. 

The door 

 
Door improves the insulation. Two solutions are possible :  
 

Insulate  an  existing  door  with  the  same  insulation  materials  used  for  the  walls  of  the 

cellar. 

Provide a tight seal between the door frame and all sides of the door with a strip of foam 

rubber for example.  

 

Use a special designed WINEMASTER isothermal door 

with polyurethane and a sealing foam 

rubber. 

 

 

 

Top view

 

 

 

 
 
1.

 

INSULATED DOOR 

2.

 

INSULATION 

3.

 

SEALING TAPE 

 

1.2.3. 

Insulation of other elements 

 

Avoid  placing  a  wine  cabinet  or  freezer 

which  generates  heat  in  the  cellar.

  The  central  heating 

pipes should be re-isolated 

during their passage through the cellar. 

 
 
 
 
 
 
 

 

 

Summary of Contents for WineIN50+

Page 1: ...N50 INFORMATION STATED ON THE NAMEPLATE OF THE APPLIANCE o Model o Serial N o Date of purchase IMPORTANT It is recommended to note the serial number here above It will be necessary for ordering spare...

Page 2: ...tion 12 2 1 6 Grids installation 13 2 2 Installing the water drainage system 14 3 USING THE WINE CONDITIONING UNIT WINEMASTER 15 3 1 Connecting the air conditioner WINE IN50 15 3 2 Plugging in the win...

Page 3: ...to ever give satisfy you we hope that your wine conditioning unit WINEMASTER will bring you great storage and best wines aging for an incomparable pleasure Because the customer is at the heart of all...

Page 4: ...t least 16 Amps The insulation quality and thickness has to be in accordance with the volume of the cellar and the set temperature The cooling performance is dependant from the outside temperature The...

Page 5: ...e insulated ducts in the inside of the cellar hot air inside the room you have to ventilate the room and non permanent 35 C It is recommended to evacuate the hot air to the outside with ducts if possi...

Page 6: ...unctioning of the WINEMASTER A good insulation enables you to maintain a stable temperature and humidity level The chart on the next page will allow you to determine the type and thickness of insulati...

Page 7: ...0 50 50 60 60 60 70 70 70 80 80 80 1 2 1 Insulation of walls ceiling and floor Type of insulation panels You can select among the following type of panels Usual panels Complex panels insulation is cov...

Page 8: ...appropriate material 1 2 2 The door Door improves the insulation Two solutions are possible Insulate an existing door with the same insulation materials used for the walls of the cellar Provide a tig...

Page 9: ...L RULES OF ELECTRIC INTALLATIONS location for the air conditioner length of duct as short as possible No obstacle in front of ventilation helps flow of cold air moving Level the supports in order to a...

Page 10: ...lation 2 1 1 Composition of the ducting kit Possibility of ordering additional parts 2 1 2 Examples Guidance in all elbow directions Possibility of ordering an additional kit 2x2 meter isolated straig...

Page 11: ...conditioner on to the isolated pipes There is no collar the pipes are equipped with lip seals put the reduction with the gasket at the other end of pipe 2 1 4 Wall drilling Drill 2 holes diameter 165...

Page 12: ...air conditioner at the site wanted while making pass the sheath through the hole in the insulation 2 1 6 Installation of the grids ATTENTION each case is composed of 2 grids blowing and aspiration it...

Page 13: ...e telescopic sleeve and the hole of the wall thanks to insulating material Polyur thane foam 1 Sleeve small part 2 Sleeve great part place the frame on the telescopic sleeves trace the clamp holes Rem...

Page 14: ...OT BE WEDGES OR MAKE a LOOP Upwards The collecting tray is likely to overflow if the pipe is not directed downwards Important After transport or maintenance wait for 24 hours before switching on the a...

Page 15: ...et the display indicates the temperature of the to the thermostat setting the fan starts up immediately to the thermostat setting the fan doesn t start The power outlet must be accessible after instal...

Page 16: ...ostat indicates ON during 1 second thermostat will run an automatic defrost time several times a day During tion the compressor is stopped only the fan is functioning at low speed producing during thi...

Page 17: ...attached In all other cases the intervention of a technician is necessary The low pressure safety device protects the compressor in case of certain malfunctions evaporator ice setting bad exchange on...

Page 18: ...formity with this User Manual His application is conditioned by the presentation of the purchase invoice or for lack of its copy 5 4 Exclusions and limitations of warranty The warranty can refused in...

Reviews: