This air conditioner features a manual reset high pressure safety switch and a self-resetting low pressure
safety switch located under the outdoor unit cover.
The high pressure safety switch protects the compressor in case of abnormal pressure rise which can be
due to several causes (obstruction of the suction or the blowing of the outdoor unit, clogging of the filter,
fan failure of the outdoor unit, poorly ventilated room where the outdoor unit is located, proximity to
obstacles disturbing the air flow ...).
In the event of lockout , the simple resetting of the device after deleting the cause is sufficient (see
attached). In all other cases, the intervention of a technician is necessary. The low-pressure safety device
protects the compressor in case of certain malfunctions (evaporator ice setting, bad exchange on the
evaporator, low outside temperature at starting, fan failure of the indoor unit, lack of fluid due to leakage
...). However, is being a device with automatic reset, it is appropriate in the case where the problem
persists to stop the air conditioner until the intervention of a technician.
4.3
Thermostat wiring
1.
purple (fan speed)
2.
red (heating resistance)
3.
Brown (power phase)
4.
Black (compressor)
5.
brown (alimentation phase)
6.
blue (neutral)
7.
red (probe)
8.
white (probe)
If you remove the front cover, tighten the ground screw (marked
) with a screwdrivers
with a tightening torque of 1,5 N.m
4.4
Condensate drain
Check and clean at least once a year the drain ( possible clamping)