TECHNICAL DATAS 

 

WINESP40DUPRO 

 

Outside unit 

Inside unit

 

Weight of units 

35 kg 

26 kg 

Dimensions H x L x D 

408 x 633 x 415 

317 x 638 x 546 

Temperature setting

 

Preset at 12°C, adjustable between 4 & 15°C 

*

 

Maximum outside temperature.

 

40°C 

**

 

Cooling power

 

900 W at 15°C

 

**

 

 

Electricity supply 

230/240V-50 Hz

 

 

Cooling power 

600 W

 

 

Heating power 

500 W

 

Gas 

R404A 

 

The circuit breaker must be at least 

16 Amps. 

 

The insulation has to be in accordance with the volume of the cellar and the set temperature

.

 

 

**

 The cooling performance is dependant from the outside temperature. Therefore, the set temperature 

of 12°C for the cellar cannot be maintained if the outside temperature reaches the 40°C. 
If the thermal safety functions to often, there is a risk for the compressor to be damaged. In all cases, it 
must be avoid that the outside 

temperature remains at 40°C

, this high temperature should be limited 

to the summer period. 
 

VENTILATED COLD OR  « NO FROST »

 

 

The advantages of « ventilated cold »: 

No frost other than on the evaporator. 

Automatic defrosting and maximized refrigeration efficiency. 

Cold distribution improved by a permanent air circulation (without air stratification). 

The circulation of air allows maintaining the pre-selected temperature throughout the cellar 

.

 

 

Summary of Contents for SP40DUPRO

Page 1: ...ent carefully INDICATIONS STATED ON THE NAMEPLATE OF THE UNIT o Model o Serial N o Purchase date UTILISATION WINESP40DUPRO Page 2 Installation and user manual please keep this document carefully SP40D...

Page 2: ...ng connection 12 3 5 Electric connection 12 3 5 1 Connection of outside unit 12 3 5 2 Connection of inside unit 12 3 5 3 Plugging 12 3 5 4 Wiring drawing 13 3 6 Installation of the water drain system...

Page 3: ...TER will bring you great storage conditions and best wines aging for an incomparable pleasure Because the customer is at the heart of all our thoughts we want to support you in your first steps and le...

Page 4: ...cooling performance is dependant from the outside temperature Therefore the set temperature of 12 C for the cellar cannot be maintained if the outside temperature reaches the 40 C If the thermal safe...

Page 5: ...GUIDE D INSTALLATION ET D UTILISATION WINESP40DUPRO Page 6 Technical drawing Outside unit Inside unit Thermostat Wiring brox...

Page 6: ...ted by frigorific ducting pipes and electric connections The ducting pipes length between both unit should not exceed 20m The unit must be installed outside or in a room Place the unit in order the ai...

Page 7: ...ntrusion which can alter their regulation View 1 WALL 2 INSULATION MATERIAL 3 GROUND LEVEL 4 FLOOR 5 CEILING 6 INSULATED DOOR IMPORTANT The WINEMASTER warranty is only valid if the insulation is in co...

Page 8: ...ical composition is not attacked by the rodents Floor insulation The floor of the cellar must be able to support the shelves and the stored wine Thus it s necessary to choose insulation with adequate...

Page 9: ...3G1 5mm for the connection of wiring box Copper pipes 1 4 3 8 for the cooling connection Screws and tools for fixing the outside unitInstallation of the outside unit Trace and drill the holes Brackets...

Page 10: ...ius elbow 175 mm Do not reduce the duct section The suction and blowing should in no way be even partially obstructed The blowing and suction should be separated to avoid a resumption of the air suppl...

Page 11: ...HE PIPE CONNECTION HAS TO BE UNDERTAKEN BY A PROF gas nitrogen Connect the 2 units by a copper line 1 4 for the la line The nuts are provided Put them on the copper rigid pipe before maximum elevation...

Page 12: ...GUIDE D INSTALLATION ET D UTILISATION 3 5 4 Wiring drawing UTILISATION WINESP40DUPRO Page 13...

Page 13: ...UGGING THE AIR CONDITIONER WINEMASTER The thermostat indicates the temperature in the wine cellar with a precision of 2 C A temperature variation of the air doesn t mean the same variation of the liqu...

Page 14: ...ing fan on high speed Red light defrost Red light heating mode engaged resistance 4 2 2 Standby mode Standby mode maintain 3 seconds on button 1 The compressor stops and the fan turns at low speed The...

Page 15: ...ped with a washable and reusable filter Unscrew the 2 plastic screws 1 Remove the filter cover 2 Take the filter out 3 Wash the filter with warm water Once the filter cleaned and drained replace the f...

Page 16: ...6 1 Installation above the air conditioned room 6 2 Installation beside the air conditioned room UTILISATION WINESP40DUPRO Page 17 EXAMPLE OF INSIDE UNIT INSTALLATION Installation above the air condi...

Page 17: ...ll appliance installed and used in conformity with this user manual His application is conditioned by the presentation of the purchase invoice or for lack of its copy 7 4 Exclusions and limitations of...

Page 18: ...GUIDE D INSTALLATION ET D UTILISATION WINESP40DUPRO Page 19...

Reviews: