background image

G

UIDE D

'

INSTALLATION ET D

UTILISATION  

6. 

EXAMPLE OF INSTALLATION OF INSIDE UNIT

6.1. 

Installation above the air conditioned room

6.2. 

Installation beside the air conditioned room

 

 

UTILISATION  

WINESP40DU4

 

/

 

WINESP40DU8 

 

OF INSTALLATION OF INSIDE UNIT 

above the air conditioned room 

 
 

 
 
 

beside the air conditioned room 

 
 

 

Page 16

 

 

 

Summary of Contents for SP40DU4

Page 1: ...DU4 SP40DU INDICATIONS STATED ON THE NAMEPLATE OF THE UNIT o Model o Serial N o Purchase date Installation and user manual please keep this document carefully d installation et d utilisation P40DU4 SP...

Page 2: ...ble dismounting 10 3 2 6 Air flow 10 3 3 Installation of the inside unit 11 3 4 Ducts reconnection 11 3 5 Electric connection 11 3 5 1 Wiring drawing 12 3 6 Installation of the water drain system 13 4...

Page 3: ...NEMASTER will bring you great storage conditions and best wines aging for an incomparable pleasure Because the customer is at the heart of all our thoughts we want to support you in your first steps a...

Page 4: ...ng performance is dependant from the outside temperature Therefore the set temperature of 12 C for the cellar cannot be maintained if the outside temperature reaches the 40 C If the thermal safety fun...

Page 5: ...GUIDE D INSTALLATION ET D UTILISATION WINESP40DU4 WINESP40DU8 Page 5 Technical drawing Outside unit FRONT SIDE Inside unit FRONT SIDE Thermostat FRONT SIDE Wiring box FRONT SIDE...

Page 6: ...depending the model distance between both units should not exceed 4 or 8m The unit must be installed outside or in a room Place the unit in order the air suction and air rejection are not disturbed En...

Page 7: ...ity intrusion which can alter their regulation View 1 WALL 2 INSULATION MATERIAL 3 GROUND LEVEL 4 FLOOR 5 CEILING 6 INSULATED DOOR IMPORTANT The WINEMASTER warranty is only valid if the insulation is...

Page 8: ...hemical composition is not attacked by the rodents Floor insulation The floor of the cellar must be able to support the shelves and the stored wine Thus it s necessary to choose insulation with adequa...

Page 9: ...R WINEMASTER of required material A cord 3G1 5mm for the connection of wiring box Installation of the outside unit Trace and drill the 6 holes for fixing the brackets as indicated Brackets installatio...

Page 10: ...e brackets Screw the 4 screw washer M6 using a key of 10 Unscrew the cable clamp 1 to release the cable Unscrew the cover from the sealed box 2 Unscrew and release the cable SUCTION Page 10 Use the 2...

Page 11: ...perature when the unit produces cold Provide openings suction and blowing Provide space for electrical connections and the condensate drain with the unit These grids are adapted to the the ducts and c...

Page 12: ...GUIDE D INSTALLATION ET D UTILISATION 3 5 1 Wiring drawing UTILISATION WINESP40DU4 WINESP40DU8 Page 12...

Page 13: ...nwards PLUGGING THE AIR CONDITIONER WINEMASTER The thermostat indicates the temperature in the wine cellar with a precision of 2 C A temperature variation of the air doesn t mean the same variation of...

Page 14: ...cooling fan on high speed Red light defrost Red light heating mode engaged resistance 4 2 2 Standby mode Standby mode maintain 3 seconds on button 1 The compressor stops and the fan turns at low spee...

Page 15: ...aning The outside unit is equipped with a washable and reusable filter Unscrew the 2 plastic screws 1 Remove the filter cover 2 Take the filter out 3 Wash the filter with warm water Once the filter cl...

Page 16: ...LATION OF INSIDE UNIT 6 1 Installation above the air conditioned room 6 2 Installation beside the air conditioned room UTILISATION WINESP40DU4 WINESP40DU8 OF INSTALLATION OF INSIDE UNIT above the air...

Page 17: ...to all appliance installed and used in conformity with this user manual His application is conditioned by the presentation of the purchase invoice or for lack of its copy 7 4 Exclusions and limitation...

Reviews: