2.4 INSTALLING THE DUCTS

The connections must be sealed to prevent condensation forming on the walls of the air-conditioner.

Take it round several times to ensure
a good seal.

Stick the adhesive tape across the
flue collar and the duct.

Place the inside duct on the flue

collar

Screw up the ring clamp and repeat
the operation on the other flue collar.

Close the head of the ring clamp after
tightening it manually.

Position the insulation duct then the
ring clamp.

2.5 INSTALLING THE WATER FLUE

Connect the free end of the PVC
tubing to a wastewater point or
retention tank. Avoid "counter-slopes"
or "siphons".

Slide on the PVC tubing.

Screw the bend, supplied with the
equipment, on the right side of the
device.

Important : Wait for 24 hours before switching the air-conditioner on.

W

INEMASTER

 C50 IN 

USER

 

GUIDE

03/2003

Page 29

Summary of Contents for C50 IN

Page 1: ...Page 28 2 3 INSTALLATION EXAMPLES Page 29 2 4 INSTALLING THE DUCTS Page 29 2 5 INSTALLING THE WATER FLUE Page 29 3 USING THE WINEMASTER C50IN AIR CONDITIONER Page 30 3 1 CONNECTING THE AIR CONDITIONE...

Page 2: ...recommendations Winemaster will provide the optimal ageing conditions for your treasured wine collection You have to read the installation and operating guide for your FONDIS WINEMASTER cellar air co...

Page 3: ...his op ration is made with isolated s ducts in the wine cellar 1 1 HOT AIR OUTLET If the WINEMASTER hot air outlet is indoors the room must be well ventilated to ensure that the temperature does not e...

Page 4: ...side with a wooden or plaster panel The panel facing is important it protects the insulation from shocks and guarantees long life Do not use mineral fibre insulation Glasswool stonewool because it sto...

Page 5: ...SOTHERMAL DOOR lined with polyurethane foam It includes a seal around its periphery with a magnetic closure 1 2 5 INSULATION OF OTHER ITEMS A fridge or another appliance producing heat must not be pla...

Page 6: ...2 2 DIMENSIONS 2 3 INSTALLATION EXAMPLES WINEMASTER C50 IN USER GUIDE 03 2003 Page 28...

Page 7: ...eat the operation on the other flue collar Close the head of the ring clamp after tightening it manually Position the insulation duct then the ring clamp 2 5 INSTALLING THE WATER FLUE Connect the free...

Page 8: ...the thermal inertia of the liquid The thermostat as been set by factory at 12 C When you start the cellar wine you should verify and if need modify the temperature following instructions below The IO...

Page 9: ...NG THE WINEMASTER AIR CONDITIONER THE DUST FILTER It is essential to replace the dust filter in the air conditioner as soon as necessary and at least once a year If it is clogged the air conditioner c...

Page 10: ...NDIS after sales service 5 2 TERMS OF APPLICATION OF THE GUARANTEE The contractual guarantee applies to all devices installed and used in accordance with the Installation and operating guide Applicati...

Page 11: ...sse suivante FONDIS SA LIBRE REPONSE 90010 68804 THANN C dex INSTALLATEUR DATE D INSTALLATION DATE D ACHAT N DE S RIE CACHET DU POINT DE VENTE TYPE NOM PR NOM ADRESSE CODE POSTAL VILLE PAYS Nous vous...

Page 12: ...de Adresse schicken FONDIS S A F 68801 THANN CEDEX KAUFDATUM SERIENNUMMER STEMPFEL DES FACHGESCH FTES MODELL NAME VORNAME ADRESSE PLZ ORT LAND Bitte geben Sie hier an wie Ihre Weinklimaanlage installi...

Page 13: ...ed ________ FIRST NAME______________________________ LAST NAME_____________________________________ ADDRESS_________________________________________________________________________________ POSTAL CODE...

Page 14: ......

Page 15: ......

Page 16: ......

Reviews: