Advanced Settings--
Special access required.
Contact Wine Guardian
Service Department for
access code
Setting 8
Press “Mode” button to advance to Setting 8.
Press the up or down arrow buttons to adjust
number to the access code. Press “Mode”
button to continue onto setting 9 through 19.
Compressor anti-short
cycling time
Setting 9
Press “Mode” button to advance to Setting 9.
Press the “Up” or “Down” arrow buttons to
adjust to the desired time in one (1) minute
increments. Maximum is 10 minutes, minimum is
0 minutes.
Compressor anti-short cycling time is the amount of
allowable time between compressor stop and
restart. Rapid start/stop of compressors can cause
premature failure. Factory default is 5 minutes.
WINE GUARDIAN DOES NOT RECOMMEND
SETTINGS LOWER THAN FACTORY DEFAULT.
Set up remote sensor
or thermostat
Setting 10
Press “Mode” button to advance to Setting 10.
Press the “Up” or “Down” arrow buttons to
adjust to the desired setting.
rS = Remote sensor
rI = Remote interface
LI= Local interface – Through-the-wall unit only
A = Averaging – Jumper position within sensors
must be adjusted. See page 28.
Room sensor calibration
Setting 15
Press “Mode” button to advance to Setting 15.
Press the “Up” or “Down” buttons to adjust to
the desired set point. Maximum setting is +2°C,
minimum setting is -2°C. Factory default is zero
(0). Sensor calibration set point changes the
actual display reading (temperature only) by the
value of this setting.
Example: Sensor reading = 13 Deg C
Setting 15 set to +2
Display reading = 15 Deg C