Installation of the Wine Guardian Remote Sensor
The Remote Sensor is a combination temperature and
humidity sensor only. It is designed to be mounted within the
wine cellar and can be used in combination with the Remote
Interface Controller or up to three additional Remote Sensors
to read and control multiple areas within the wine cellar.
*** The remote sensor is now only available in black ****
Mounting the remote sensor
1.
Disconnect the communication cable from the side of
the Wine Guardian unit and the remote sensor. Install
the communication cable within the wall and/or ceiling
structure of the wine cellar to the desired controller
mounting location.
Important
A splitter device has been supplied within the Remote Sensor
kit. The splitter device must be mounted at the WG unit as
shown. DO NOT mount the splitter device at the back of the
Remote Interface Controller or to the back of the Remote
Sensor as this WILL cause component or system damage.
2.
Mount the Remote Sensor on a solid surface away from
doors, corners, air outlets, drafts or heat generating
equipment. Do not mount the Remote Sensor directly on an
outside wall or wall adjacent to a boiler room. Use a piece of
foam insulation behind the sensor to insulate it from a hot or
cold surface. The recommended height is 1.2 to 1.5 meters
above the finished floor.
3.
Remove the sensor cover plate by removing the two allen
head screws at the top of the cover using the allen head
wrench provided in the kit.(Fig.2) Mark the mounting
points at the desired location within the wine cellar. Also
mark the location of the communication cable connection
as this area will require sufficient clearance, for instance
3.8cm hole in the wall for flush mounting of the sensor
plate
.
Fig.2
Fig.1