Maintenance Schedule
Monthly
(or quarterly depending on experience with individual cellar)
√
Check for noise or vibration.
√
Check for short-cycling of the system - a turning on and off of the compressor unit
more than eight (8) times/hour.
Yearly
(in addition to monthly)
√
Check evaporator and condenser coils for dirt – use a vacuum with a brush attachment
to clean the coils.
√
Clean condensate pan under the evaporator coil by flushing. Be careful to keep the drain
pans clear of any and all debris.
√
Inspect cabinet for corrosion or rusting – clean and paint.
√
Inspect for dirt buildup on or inside the unit. Clean system by vacuuming or wiping it
down.
√
Check for loose insulation, fasteners, gaskets or connections.
√
Check the wiring connections and integrity of cords.
√
Examine condenser duct (if option is used) for any cracks or breach.