Wiring the Fan Coil Unit for Power
DANGER
ELECTRICAL SHOCK HAZARD
RISK OF SERIOUS INJURY OR DEATH
The electrical outlet and wiring installation must meet the national and local
building codes.
DO:
Match the electrical wiring to the cord provided on the Wine Guardian.
Provide dedicated circuit and wiring for the system.
Match the wiring and breaker size to the rated load as shown on the serial
plate and in this guide. See sample serial plate illustration below.
.
DO NOT:
DO NOT MODIFY THE PLUGS IN ANY WAY!
Do not use extension cords.
Plug the unit into the wall outlet. Gently pull on the plug to make sure it is tight.
IMPORTANT
The electrical power supply must be either 115 volt or 230 volt AC 1 phase 60 cycle, depending
on the model of the unit, and cannot vary
more than plus or minus 4% or damage may occur
to the unit.
Electrical
230/1/60
Electric Heat Amps
(opt.)
6.7
Evaporator Fan Amps
0.8
Humidifier Amps (opt.)
0.3
Total Unit Amps (w/o opt.)
0.8
Crankcase Htr. Amps.
0.2
Min. Circuit Amps (w/o opt.)
1
Refrigerant
R-134-A
275psi
Air Innovations, 7000 Performance Drive, North Syracuse, New York 13212
Ph:800-535-3295 * 315-452-7400 * Fax: 315-452-7420
Test Pressure
Model# SS088 Serial# 11L18342
Neutral
Summary of Contents for 15H0128-00
Page 11: ...11 Fig 2 Overview of the Wine Guardian fan coil Fig 1...
Page 13: ...13 Ducted split system specifications sheet...
Page 14: ...14 Wiring Diagram for SS025 and SS050 Units Fig 4...
Page 15: ...15 Wiring Diagram for SS088 Units Fig 5...
Page 16: ...16 Wiring Diagram for SS200 Units Fig 6...
Page 17: ...17 24 Volt Contactor Detail Sheet Fig 7...
Page 27: ...27 Rod Mount Fig 2 Shelf Mount Fig 3 Optional ductwork connection on same wall Fig 4...