26
Ceiling Mounting
Construct a structurally sound, level platform to place the unit on when hanging it from the
ceiling joists. The Wine Guardian is NOT designed to be suspended from the top of the unit; it
must be supported from the bottom. Angle brackets are available as an option for these types of
applications. Place the unit on a platform to ensure that the unit is supported on all four corners.
Leave adequate space on the top of the unit to remove the access doors for service.
In all cases the unit must be level to within plus or minus one-quarter inch end-to-end and plus
or minus one-either inch side-to-side for proper operation. Locate the unit as close to the wine
cellar as possible to reduce the length of the duct runs. If possible, use short and straight ducting
on all ductwork runs.
Typical Mounting Arrangements
The following illustrations are suggested mounting arrangements. These illustrations are not
intended to be complete and detailed installation drawings. For questions or help regarding
installation, contact a Wine Guardian distributor or email (
) a sketch
of the proposed area where the unit is to be installed.
Handling and Installation
1)
Mount unit on solid, level surface.
2)
Allow sufficient space for access to unit and accessories.
3)
Provide proper electrical service.
4)
Provide water to humidifier.
5)
Install drain line with proper pitch.
Floor Mount
Supply air at ceiling, low wall return
Fig. 1
Summary of Contents for 15H0128-00
Page 11: ...11 Fig 2 Overview of the Wine Guardian fan coil Fig 1...
Page 13: ...13 Ducted split system specifications sheet...
Page 14: ...14 Wiring Diagram for SS025 and SS050 Units Fig 4...
Page 15: ...15 Wiring Diagram for SS088 Units Fig 5...
Page 16: ...16 Wiring Diagram for SS200 Units Fig 6...
Page 17: ...17 24 Volt Contactor Detail Sheet Fig 7...
Page 27: ...27 Rod Mount Fig 2 Shelf Mount Fig 3 Optional ductwork connection on same wall Fig 4...