24
Planning the Installation
Addressing Items in the Planning Process
Where to locate the fan coil unit? Should it be built into the wine cellar or
mounted remote and ducted into the cellar?
How to mount the fan coil unit?
Decide where to locate the supply and return grilles in the room to achieve the
temperature gradient and circulation preferred.
Locate the electrical power outlet close to the unit.
Do not use an extension
cord!
Locate the condensing unit in a clean, dry and well-ventilated area.
Where to locate the remote interface controller and/or remote sensors?
Where to run the drain line?
Are all the parts available to complete the installation?
Performing a Pre-installation Check
Check for the proper installation of the electrical plug configuration.
Check for the properly sized breakers for both the condensing unit and fan coil
section.
Is the cellar built with adequate insulation and vapor barriers?
Are ducts installed above the ceiling or in accessible places properly sized before
being covered?
Is enough space available around the units for service and repair?
IMPORTANT
Installation of residential and commercial split systems must be performed by qualified
service technicians with proper training in the installation, start up, service, and repair of
these systems. Certification to handle refrigerants is also required.
Summary of Contents for 15H0128-00
Page 11: ...11 Fig 2 Overview of the Wine Guardian fan coil Fig 1...
Page 13: ...13 Ducted split system specifications sheet...
Page 14: ...14 Wiring Diagram for SS025 and SS050 Units Fig 4...
Page 15: ...15 Wiring Diagram for SS088 Units Fig 5...
Page 16: ...16 Wiring Diagram for SS200 Units Fig 6...
Page 17: ...17 24 Volt Contactor Detail Sheet Fig 7...
Page 27: ...27 Rod Mount Fig 2 Shelf Mount Fig 3 Optional ductwork connection on same wall Fig 4...