background image

 

16 

7. The guarantee 

 

7.1. The legal guarantee 

 

  The contractual guarantee is, to the advantage of the buyer, not exclusive of the 

legal guarantee for hidden mistakes and defects, in accordance with the condi-
tions of art. 1641 ff of the Civil Code. 

 
 

7.2. 2-year contractual guarantee 

 

 The air conditioner has a 2-year guarantee for all defects of production. 
 

 During the term of the guarantee, FONDIS replaces all parts that are demonstra-
bly defective. 

 
In case of a power failure, FONDIS replaces all defective parts, which were dam-
aged due to the intervention of the dealer or his representative. 

 
Should the cooling fail, FONDIS is entitled to demand that the appliance be re-

turned to the factory for repair. The material has to be packed and ready to be 
collected by a carrier of FONDIS. 

 
The repair works have to be carried out in accordance with the written 

agreements of the FONDIS after-sales service. 

 
 

7.3. Conditions applicable to the guarantee 

 

 The contractual guarantee applies to all appliances that were installed and used 

according to the "Instructions for installation and use". Condition for the applica-
bility of the guarantee is the presentation of the invoice from the purchase or a 

copy thereof. 

 

 

7.4. Guarantee exclusions and limits 

 

 The guarantee is NOT VALID in the following cases :  

 
- The insulation of the cellar and the installation was not carried out in accor-

dance with the presented instructions. 
 

- The failures are due to negligence, bad servicing, wrong or inappropriate use of 
the air conditioner. 
 

- The aim of the exchange of spare parts or their reparation within the guarantee 
cannot be to prolong the guarantee. 

 
- The service information was not supplied to the after-sales service.
 

 
FONDIS SA cannot under any circumstances be held responsible for the direct or 

indirect consequences of an incorrect function of the air conditioner. The guaran-
tee applies exclusively to the product supplied by FONDIS S.A. 

 

 

Summary of Contents for Wine PC15

Page 1: ...U S E R G U I D E D E F Y I N G C O N V E N T I O N WINE PC15...

Page 2: ...lation Page 8 2 3 2 Insulation of walls and ceiling Page 9 2 3 3 Insulation of the floor Page 9 2 3 4 Insulation of other elements Page 9 3 Installation of the door Page 10 4 Installation of the air c...

Page 3: ...ning systems for the conservation and ageing of wine If you follow our advice and adhere to our recommendations your wines will be able to fully develop Before installing and using your WINEMASTER FON...

Page 4: ...ughly 35 C Never the less a permanent temperature of 35 C in the exhaust air space must be avoided Such a high temperature must be reached during the sum mer season only see 1 1 Exhaust air space Capa...

Page 5: ...5 1 2 Required space mm 1 8 9 8 720 Dimension ext rieure Passage 720 624 1 8 9 8 2 0 0 0 57 35...

Page 6: ...ll edge seal 8 fixing screws plugs 8 white plastic covers 1 cartridge of silicone 1 cylinder keys set Packet 2 1 air conditioner WINECPN 1 plastic hood 1 filter 8 fixing screws 4 rings Important When...

Page 7: ...ed from all possible sources of vibration and stand on the ground rather than be attached to a wall which is more sensitive to vibrations In order to age the wine has to be protected from the light Th...

Page 8: ...related to the strict observance of the values in the table Choice of the insulation for all the cellar walls including the floor the ceiling and the door as well as to the perfect continuity of the i...

Page 9: ...with a protective layer on the inside of the cellar Polyurethane is an insulant which due to its chemical compostion is not at tacked by rodents 2 3 3 Insulation of the floor The cellar floor must be...

Page 10: ...of the wall opening MAKE SURE THE EDGES AND SURFACES OF THE OPENING ARE CLEAN AND SMOOTH 1 Apply the edge seal to the frame 1 CROSS HEADED SCREW DRIVER 2 SPIRIT LEVEL 3 SLIP JOINT PLIERS 4 MEASURING T...

Page 11: ...nd the hinges 4 The door must fit precisely into the frame in order to ensure optimal impermeability Readjust the door jamb and the hinges if necessary 5 Check the right angledness of the installation...

Page 12: ...nd the wall with silicone or acryl 7 Cover the mounting holes with the plastic covers provided for this purpose 8 Remove the protective film from the door Right angledness of the in stallation a regul...

Page 13: ...rough the cable bushing under the door opening situated on the left side 2 Place the air conditioner in the door aper ture 3 Check the height of the appliance and fix it to the door with the 4 thread...

Page 14: ...storage is 12 C Thermostat regulation indispensable when bringing the machine into service for the first time Push the button SET 3 The display 1 will flash and indicate the programmed temperature Pus...

Page 15: ...es automatically If the door is left open for too long by mistake and the compressor works more than necessary the excess water flows away through the overflow This can also happen when the cellar is...

Page 16: ...ments of the FONDIS after sales service 7 3 Conditions applicable to the guarantee The contractual guarantee applies to all appliances that were installed and used according to the Instructions for in...

Page 17: ...have to be marked with crossed out rubbish bin This symbol means that the product cannot under any circumstances be disposed of as household waste It has to be given to a special collection point for...

Page 18: ...rner co uk www winecorner co uk Wine Corner Limited 2012 We reserve the right to change product specifications and prices without prior notice Wine Corner Limited does not accept any responsibility fo...

Reviews: