Page 3: ...load event the system will be protected and remain undamaged The enclosure is made of durable plastic with LED lights to provide status indications of charge battery status and system faults as well a...

Page 4: ...29 6V Overcharge Recovery 13 2V 26 4 V Over discharge Disconnection 11 1V 22 2V Over discharge Reconnection 12 5V 25 0V Temperature Compensation 4 0 mV o C 2V 1 4 2 Physical Specifications Parameter V...

Page 5: ...mounting surface 3 Tighten all the fasteners to ensure the controller cannot slide in any direction IMPORTANT For best results mount the charge controller and batteries as close to the panels as pract...

Page 6: ...avoid touching any conductors in the system circuit to avoid electric shock 3 Connect the Load Optional If you have a 12VDC application connect the wires from the appliance to the load port on the ch...

Page 7: ...or in some instances it may take a few moments longer 3 2 1 Charge LED When the connected solar panel is exposed to sunlight the Charge LED will be green indicating that the system is charging normal...

Page 8: ...ay begins to flash 5 seconds Press the button repeatedly to choose the desired mode number When the desired number is selected stop pressing the button and wait for number to stop flashing indicating...

Page 9: ...1 Night ON 2 Hours delay OFF 02 Night ON 12 Hours delay OFF 12 or 2 Night ON 3 Hours delay OFF 03 Night ON 13 Hours delay OFF 13 or 3 Night ON 4 Hours delay OFF 04 Night ON 14 Hours delay OFF 14 or 4...

Page 10: ...PV voltage is within specifications to the open circuit voltage rating of the panels but the battery voltage is low the charge controller may not be charging the battery and it may be damaged The cha...

Page 11: ...t submit a service request within the Warranty Period by contacting Windy Nation in writing or via telephone and obtaining a Returned Materials Authorization RMA number This RMA must be obtained befor...

Page 12: ...ERSON 5 4 4 Limitation of Liability UNDER NO CIRCUMSTANCES WILL WINDY NATION OR ITS AFFILIATES OR SUPPLIERS BE LIABLE OR RESPONSIBLE FOR ANY LOSS OF USE INTERRUPTION OF BUSINESS LOST PROFITS LOST DATA...