33
3.
For the Electrician
All of the electrical connections are at the top, underneath the control panel cover. On the left of the control panel
is the main board; the connection terminals (screwless cage-spring-type terminals) for MESplus control or REG
control are on the right – Fig. 92.
To access the control panel:
– Remove the cladding cover – Fig. 86.
– Remove the switch cover by removing the 2 screws at the back of the cover – Fig. 87. Disconnect the InfoWIN
cable (Fig. 88) and remove switch cover by raising it.
– Remove insulation from the coasting surfaces cover – Fig. 89.
– Remove the control panel cover by unscrewing 3 screws from front, and pull out the InfoWIN cable and grom-
met. Push the cover backwards and remove it – Fig. 90.
Fig. 86 Remove the cladding cover
Fig. 87 Loosen the 2 screws on the switch cover
Fig. 88 Disconnect the InfoWIN cable and
remove the switch cover
Fig. 89 Remove insulation
Fig. 90 Remove the 3 front screws, pull out the InfoWIN
cable and grommet, push back cover and
remove it
InfoWIN cable
with grommet
Fig. 91 For service purposes, the switch cover
can be hooked into the door
Tip!
For service purposes, the switch cover can be hooked into the door – Fig. 91.