Connector panel
01900xxxxx iPOS plus Advanced – User Manual 38
Disconnecting cables
Never unplug a cable by pulling on the cable; always take direct hold of the
plug itself. Follow the procedure below when disconnecting cables:
Turn off all power and equipment switches.
Remove the cable cover.
Unplug all power plugs from the grounded-contact power sockets.
Unplug all data communication cables from the sockets of the data
networks.
Unplug all cables from the devices.
With MINI-DIN plugs ( Wincor Nixdorf
keyboards), the plug remains inserted
until released.
Pull the plastic covering from the connect-
ing socket with your thumb. The lock is
released. The metal of the plug is visible.
To release a RJ12 plug push the latch under
the plug to the top.
You loosen the USB-A- connector by push-
ing the covering of the connector.