INSTALLATION AND 
OPERATORS MANUAL

INDUSTRIAL PORTABLE

WT3000H

WC5000H
WC6000H

WC6000HE

WINCO INC.
225 S. CORDOVA AVE.
LECENTER, MN  56057
507-357-6821
SERVICE DEPT.
507-357-6831

Summary of Contents for WC5000H

Page 1: ...1 1204 00 60706 221 INSTALLATION AND OPERATORS MANUAL INDUSTRIAL PORTABLE WT3000H WC5000H WC6000H WC6000HE WINCO INC 225 S CORDOVA AVE LECENTER MN 56057 507 357 6821 SERVICE DEPT 507 357 6831...

Page 2: ...ARE 11 TROUBLESHOOTING 11 WARRANTY INFORMATION 12 PROPER USE AND INSTALLATION You must be sure your new engine generator set is Properly serviced before starting Operated in a well ventilated area Pro...

Page 3: ...into the earth 2 FIRE HAZARD Gasoline and other fuels pres ent a hazard of possible explosion and or fire a Do not refuel when the engine is running or hot b Keep fuel containers out of reach of chil...

Page 4: ...tments will not allow enough free flow of fresh air to reach the engine generator set for cooling and will cause the unit to overheat damaging both the engine and generator Small compartments will als...

Page 5: ...AGE RUNNING THE GENERATOR SET UNDER THESE CONDITIONS MAY RESULT IN DAMAGING THE GENERATOR STATOR AS WELL AS THE MO TOR WINDING The heavy surge of current required for starting motors is required for o...

Page 6: ...ric start engines are NEGATIVE GROUND Use extreme caution when connecting the battery Connect the NEGATIVE battery terminal to GROUND For your safety always connect the positive battery cable to the b...

Page 7: ...s turned off This releases the throttle arm allowing the governor to take over and open the throttle The engine will respond and come up to the governed speed 3600 rpm 3 When the electrical load is tu...

Page 8: ...ing fuel from the fuel tank b Start the engine and allow it to run until all the fuel in the carburetor and the fuel lines has been used up and the engine stops c While the engine is warm drain the oi...

Page 9: ...ulating based on engine speed The engine governor will automatically adjust itself to the load No harm to the generator will result if it is operated with no load connected Proper utilization of the r...

Page 10: ...ed to the generator at that time Im proper loading of the generator set constitutes abuse and will not be covered by warranty ENGINE CARE If major engine service or repair is required contact an autho...

Page 11: ...y duty double sealed ball bearing They require no maintenance or lubrication b Receptacles Quality receptacles have been utilized If a receptacle should become cracked or otherwise damaged replace it...

Page 12: ...to 24 months from date of purchase In no event is WINCO liable for incidental or consequential damages Note Some states do not allow limitation on the duration of implied warranty and some states do n...