Winco W15PTOS/E Operator'S Instruction Manual Download Page 5

Page 3

60706-180

0310-00

B. The foundation must be solid enough to absorb generator

starting and reflected load torque during operation.

C. The foundation surface should be flat.

D. Space is required around the generator for mounting

switching devices, making connections, and for servicing.

E. The generator mounting bracket must rest evenly and

firmly on the foundation. Install shims if necessary to even
out the foundation under the mounting pads then bolt the
generator firmly in place.

TRAILER MOUNTING

Mount the generator on a trailer if you plan to use it as a
portable power source.  When selecting or building a trailer to
mount the generator, consider the following points:

A. The trailer construction must be strong enough to support
the generator.

B. The design of the trailer must enable the trailer to remain
stable during operation, and to resist tipping caused by
generator starting and reflected load torque.

WARNING:  Personal Injury & Equipment Damage
TRAILER MAY TIP OVER AND CAUSE INJURIES IF
WHEELS ARE NOT SPACED FAR ENOUGH APART.

Optional Trailer Part Number TDM75

C. The trailer height and mounting position of the generator on

the trailer should enable aligning the drive shaft (tumbling bar)
in a straight or nearly straight line between the power take-off
and generator input shafts.  Misalignment must be less than 10
degrees during generator operation, even though the mechani-
cal design of the tumbling bar would allow greater misalign-
ment.

D. The generator mounting area of the trailer bed should be
flat.

All four generator mounting pads must rest firmly on the trailer
bed.  Install shims if necessary to even out the bed under the
mounting pads, then bolt the generator firmly in place.

WINCO THREE POINT HITCH

Optional 3-Point Hitch Part Number TPH240

WARNING:  Personal Injury & Equipment Damage
WHEN USING THE 3-POINT HITCH ASSEMBLY ALL THREE
POINTS MUST BE ATTACHED TO THE TRACTOR. FAIL-
URE TO DO SO WILL CAUSE THE GENERATOR TO TIP
WHEN LIFTING IT DAMAGING BOTH THE T-BAR AND THE
GENERATOR.

A. The three point hitch must be attached to the tractor at all

times during operation.

B. When operating the generator the three point hitch and

generator must be sitting on flat level ground.  All four deck
pads must be in constant contact with the ground at all
times.  This will reduce the vibration in both the generator
and the tumbling bar.

C. For safety the generator must be bolted to the three point

hitch deck using all four mounting bolts

Summary of Contents for W15PTOS/E

Page 1: ...OPERATOR INSTRUCTION MANUAL COMPACT PTO GENERATORS COMPACT SERIES TRACTOR DRIVE GENERATOR W15PTOS E ...

Page 2: ... YOUR PTO GENERATOR IS IN OPERATING CONDITION AND READY FOR USE WHEN THE NEED ARISES PARTS LIST PARTS DRAWINGS AND WIRING DIAGRAM PERTAINING TO YOUR UNIT ARE ENCLOSED WITH THIS MANUAL This manual covers the latest compact portable tractor driven Power Take Off PTO generator model from Winco This 15 000 watt generator is designed to provide120 240V single phase electrical power for standby and util...

Page 3: ...nearby and know its proper use Fire extinguishers rated ABC by NFPA are appropriate 3 DEADLY EXHAUST GAS Exhaust fumes from any engine contain carbon monoxide an invisible odorless and deadly gas that must be mixed with fresh air a Operate only in well ventilated areas b Never operate indoors 4 NOISE HAZARD Excessive noise is not only tiring but continual exposure can lead to loss of hearing a Use...

Page 4: ...UTION Equipment Damage DO NOT invert generator during unpacking The Gearcase contains oil which will leak out if inverted during unpacking Unpack the generator as follows 1 Remove the carton 2 Examine the unit for damage 3 Find the small subpack carton packed in the large carton Be careful not to throw away the subpack carton with the large carton 4 Open the subpack carton and make sure it contain...

Page 5: ... generator on the trailer should enable aligning the drive shaft tumbling bar in a straight or nearly straight line between the power take off and generator input shafts Misalignment must be less than 10 degrees during generator operation even though the mechani cal design of the tumbling bar would allow greater misalign ment D The generator mounting area of the trailer bed should be flat All four...

Page 6: ...ional Electrical Code DANGER PERSONAL INJURY IF THE GENERATOR IS TO BE USED AS A STANDBY POWER SOURCE A MANUAL TRANSFER SWITCH MUST BE INSTALLED TO SEPARATE THE GENERATOR AND THE COMMERCIAL POWER LINES THE SWITCH MUST ISOLATE THE GENERATOR FROM THE COM MERCIAL POWER LINES AND THE LOAD WHEN THE GENERATOR IS ON STANDBY AND MUST ISOLATE THE COMMERCIAL POWER LINES FROM THE LOAD AND THE GENERATOR WHEN ...

Page 7: ...R BEFORE WIRING IMPORTANT Use copper wire only Do not use tinned conductors Sizing cable see NEC 400 5 CORD SIZE 4 4 conductor cord SO 1 25 inch dia max Figure 2 To assemble and wire the load disconnect plug proceed as follows 1 Strip outer jacket 2 3 4 2 Cut and strip leads to lengths specified for the particular plug 3 Disassemble cable clamp and top cover 4 Remove one blade at a time insert the...

Page 8: ...he output reaches approximately 240 to 245 volts in green portion of voltmeter scale 5 Plug 4 wire load cord set into receptacle Place transfer switch in the emergency position 6 Place the load circuit breaker in the on position If the breaker trips move manual transfer switch to off or normal position Check for short circuit or grounded connection in the load cable to the double throw switch and ...

Page 9: ...ling causes overheating and oil seal failure 2 The generator bearings are factory lubricated and sealed and require no further lubrication 3 The splined generator input shaft should be cleaned and lubricated with a thin film of grease before and after each use of the generator See Figure 6 for lubrication sched ule 4 The drive shaft tumbling bar requires greasing Keep the universal joints in the c...

Page 10: ...ace if defective Low Speed High line loss Indicated by lower voltage at load than at generator terminals 1 Undersized overloaded 2 Defective governor 3 Low power worn engine LOW OUTPUT VOLTAGE POSSIBLE CAUSE Loss of residual magnetism Usually occurs only after disassembly of field frame or severe mechanical stress abuse Grounded or shorted rotor winding Open excitor circuit in stator Defective dio...

Page 11: ... Control Box Sheet Metal 2 91370 000 1 Voltmeter 0 300 VAC 3 300136 1 Receptacle NEMA 14 60R 4 50766 000 1 Receptacle NEMA 5 20R 5 91286 001 1 Circuit Breaker 20 AMP 120 VAC 6 63708 000 1 Ground Lug 7 57030 005 1 Circuit Breaker 60 AMP 240 VAC NI 300137 1 Plug NEMA 14 60P Supplied with the Unit ...

Page 12: ...80 2 1 Receptacle Box Cover 6 300086 1 1 Safety Shield 7 15209 000 1 Safety Decal 8 Z 2516 1 Warning Decal 9 Z2553 1 Operating Instructions Decal REF PART QTY DESCRIPTION 10 Z9941 1 Oil Fill Hole Decal 11 Z2568 1 PTO Danger Decal 12 91369 003 1 515 RPM Decal 13 53113 001 1 WINCO Decal 14 62487 003 2 5 Loom 5 8 NI 300323 112 1 Capacitor 31 5 mf 425 V NI 300323 212 2 Capacitor 35 mf 450 V NI 300153 ...

Page 13: ...RANSPORT DESCRIPTION PART NO 1 SUPPORT TONGUE QTY 2 300081 2 HITCH TONGUE QTY 2 300082 3 TONGUE 300083 4 AXLE QTY 2 300085 5 SUPPORT AXLE 300164 6 SUPPORT PTO SHAFT 300161 1 7 SUPPORT PTO SHAFT 300161 2 8 TIRE RIM PNEUMATIC QTY 2 43657 000 ...

Page 14: ...allow the exclusion or limitation of incidental or consequential damages so that above limitation or exclusion may not apply to you This warranty gives you specific legal rights you may have other rights which vary from state to state This warranty is limited to bench labor and parts only no allowance will be made for travel time or removal and reinstallation of the PTO unit WINCO does not warrant...

Page 15: ...60706 180 0310 00 ...

Page 16: ...60706 180 0310 00 225 SOUTH CORDOVA AVE LE CENTER MN 56057 1 507 357 6831 ...

Reviews: